background image

 

 

Page 1 of 2 

Product Profile 

DSP-22 Vehicle Detector 

All this and a 5-Year Warranty too! 

 
             

 

Features 
 

 

Works on any in-ground 
inductive loop from 20 to 
2000 microhenries.

 

 

 

Designed to be cross talk 
free between other loops

 

 

 

Automatically compensates 
for loop and lead-In sizes

 

 

 

Separate Power/Fail and 
Detect LED's for both 
channels

 

 

 

Small profile, perfect for 
many installations

 

 

 

Fail safe operation

 

 

 

Operates on 12 VDC

 

 

 

This series of Diablo Controls 
detectors are covered by 
United States patent.  

 

Patent number US 7,132,959 
“Non-Interfering Vehicle 
Detection.”  

 

 

 

Available in single and dual 
channel models. Matches 
DKS® 9410-10 single 
channel or DKS® 9409-10 
dual-channel detector

 

Overview 
The DSP-22S detector will add a new dimension of simplicity to your plug-in 
detector  requirements.

 

This  series  of  Diablo's  detectors  are  covered  by 

United  States  patent  number  US  7,132,959  “Non-Interfering  Vehicle 
Detection.” These detectors are virtually cross-talk free in most applications. 
This micro-sized  detector  will  automatically  adjust  its  sensitivity  level  when 
used  on  different  sized  loops.    The  detector  loop  inductance  should  be 
between 20 and 2000 microhenries.  
 
LED Indicators 
The green Power LED will be on steady to indicate the detector is operating 
and powered.  The red  Detect LED  will turn on  when a  vehicle  is over the 
loop detection area. 
 
Detect Memory 
Power  interruptions  of  short  duration  are  ignored.  If  power  fails  for 
approximately 1 ½ seconds or less the detector “remembers” a vehicle.

 

 

Sensitivity and Reset Push Button 
The  Reset/Sens.  button  is  used  for  two  functions.    A  short  press  and 
release  of  the  button  will  reset  the  detector  and  the  LED's  will  both  flash 
from 1 to 4 times, indicating the detector's sensitivity level.  The detector is 
shipped from the factory with the sensitivity set at level 3.

 

 
If a different sensitivity level is required:

 

Push and continue to hold the button until the LED's start flashing - release 
the button immediately after the desired number of flashes.  For example, if 
the sensitivity is to be changed to level 2, push and hold the button until the 
LED's flash twice then immediately release the button.  The sensitivity level 
can always be verified by a quick tap on the push button.  This will reset the 
detector and flash the two LED's indicating the present level.

 

 

Level 1 - Very Low 

 

Level 2 - Low

 

Level 3 - Normal (Factory setting)

 

Level 4 - High

 

 
Loop or Wire Failures 
In the case of a loop circuit failure, the green LED flashes slowly (twice per 
second)  for  an  open  loop  circuit  failure.   The  green  LED  will  flash  fast  (10 
times per second) to indicate a shorted loop circuit. 
 
Fail Safe vs Fail Secure 
A fail safe detector will output “detect” when the loop circuit is failed.  This is 
always useful on a safety loop. On the free exit loop this will keep the gate 
open  until  the  situation  is  fixed.    This  is  useful  in  applications  where  it  is 
important  to  allow  traffic flow  to  continue.    A  fail  secure  detector  will  never 
output  “detect”  when  the  loop  circuit  is  failed.    This  will  keep  the  gate 
closed.    This  is  useful  in  high-security  areas  or  installations  where 
containment  is  needed.    The  DSP-11  is  a  fail  safe  detector.    Note:  Never 
use a fail secure detector on a safety loop.   
 

Отзывы: