Di-soric ID Series Скачать руководство пользователя страница 1

©

2011 di-soric

   

Step 2 — Connect the System

Connecting by RS-232 / RS-422 / RS-485

Connect the imager (

1

) to the VSID-IB-S/ VSID-A-24/5V-S interface (

2

and (

3

).

Connect the communication cable (

6

) to the host, and to the host port         

on the VSID-IB-S.

Connect the object detector (

5

) to the VSID-IB-S.

Connect the power supply (

4

) to the VSID-IB-S.

Apply power to the imager.

Hardware Configuration

Caution:

 Be sure that all cables are connected 

BEFORE

 applying power 

to the system. Always power down 

BEFORE

 disconnecting any cables.

Scanner

Networ

k

Host

1

3

2

4

5

6

Step 1 — Check Hardware

Item

Description

Part Number

1

MINI Imager

ID-04-IM1-x-x

2

Adapter 24V to 5V DC

VSID-A-24/5V-S

3

Interface Box

VSID-IB-S

4

Power SupplyM12, 3 poled

VSID-PS-IB

5

Object Detector

6

Connecting  cable 1.8 m

VSID-K-25S/9K-2

Scanner

Networ

k

Host

Hardware Required

1

3

2

4

5

6

Quick Start Guide

ID Imager Series

P/N 83-116302 Rev D

Step 3 — Position Imager

Place the imager and test symbol in a location with as little ambient light 
as possible.

Position the imager at a focal distance between 

2” 

and

 6” from the symbol

.

Tip the imager relative to the symbol to avoid glare from specular reflection. 
Avoid excessive skew or pitch. Maximum skew is 

±30°

; maximum pitch is 

±30°

).

Symbols can be rotated (tilted) at any angle; however, for best results 
symbols should be aligned with the FOV (field of view). In the case of linear 
symbols, aligning the bars in the direction of their movement (“ladder” 
orientation) will minimize the chances of blurring and No Reads.

Imager / Symbol Positioning

Step 4 — Install di-soric ID

di-soric ID Software can be found on the di-soric Tools  USB Stick that is 

packaged with the imager. 

1. Follow the prompts to install di-soric ID Software from the USB 

Stick

2. Click on the di-soric ID icon to run the program.

Note: 

di-soric ID Software can also be installed from the 

Download 

Center

 at  

www.di-soric.com

.

Refer to the user’s manual for detailed information about using di-soric ID 
to configure the imager.

 

 WARRANTY 

Standard Warranty: One Year

All di-soric products are backed by a one-year stan-
dard warranty. Full warranty details are online at 

www.di-soric.com