Di-LOG UT305H Скачать руководство пользователя страница 1

 

 

 UT305H

  

Forehead Infrared 

Thermometer User Manual

 

Dear User

 

Thank you for purchasing your ne

infrared thermometer

In order to use this product safely 

and correctly

please read this manual thoroughly

please pay particular attention to the 

precautions.

 

 

After reading this manual

it is recommended to keep it in at an easily accessible pl

a

ce

preferably close to the de

v

ice

for future reference

.

 

Limited Warranty and Liability

 

Di-LOG guarantees that the product is free from any defect in material and workmanship 

within the first year from the date of purchase

The warranty does not apply to damage 

caused by accident

negligence

misuse

modification

contamination, or improper handling

.  

If you need warranty service within the w

a

rranty period

please contact your us directly.

 

Di-LOG will not be responsible for an

special

indirect

incidental, or subsequent damage or 

loss caused by using this de

v

ice.

 

 

Introduction

 

The UT305H infrared thermometer (hereinafter referred to as the thermometer) can quickly 

and accurately determine the surface temperature by me

a

suring the infrared energy radiated 

from the target surface

It is suitable for non-contact temperature measurement.

 

        Precautions

 

•  To ensure proper use of the thermometer

please read this manual carefully before use.

 

•  To ensure safety and accuracy of the thermometer

it should only be repaired by a qualified 

professional using original replacement  parts

.

 

•  If the battery symbol on the LCD flashes

please replace the battery immediately to prevent

 

inaccurate measurement.

 

•  Inspect the product case before using the thermometer. Do not use the thermometer if it 

appear

s

 d

a

maged

Look for cracks or missing plastic

.

 

•  Avoid keeping the thermometer near high temperature environments for long periods.

 

•  To ensure measurement accuracy

please use the thermometer in the operating en

v

ironment 

[15

°

C - 30

°

C

<85% RH (non-condensing)]

.

 

•  Please use the thermometer indoors where possible.

 

•  The ambient temperature of the measured object must be stable

and it should not be 

measured in places with large airflow such as fans or air conditioning ventilation.

 

•  When changing to a new environment

please leave the thermometer for 30 minutes before

 

use.

 

•  When the target object is transported from a place where there is a large difference in 

temperature from where you intend to take your measurement

leave the object in the 

vicinity of where you intend to take the temperature measurement for 10 to 30 minutes 

to improve accuracy.

 

•  Do not use the thermometer in places with direct sunlight or electromagnetic interference.

 

•  After measuring extremely high or low temperature objects

please leave the thermometer 

for 10 minutes before next use

.

 

•  It is recommended to take three measurement of the target object and record the 

highest or lowest displayed reading.

 

•  Direct the IR (infrared) sensor 

lens to 

face the target object during measurement observing 

the optimal measuring distance outlined in the specification

, failure to observe this will 

cause inaccuracies from the actual temperature of the target.

 

• 

Infrared Thermometers are not designed to diagnose any medical condition and are 

designed to indicate temperature differential between two target objects.

 

Specifications

 

Instrument Layout

 

 

      

 

2

 

3

 

4

 

5

 

6

 

 

LCD Description

 

 

 

 

Buzzer indicator

 

 

 

HI OK LO

 

Temperature measurement alarm indicator

 

 

 

SCAN

 

Temperature measurement indicator

 

HOLD

 

Temperature hold indicator

 

 

 

Temperature unit indicator

 

 

Display of the measured temperature

 

 

Operating Instructions

 

Power On

 

In the off state, a short press of the trigger will turn the thermometer on.

 

Power Off

 

In the HOLD mode

if there is no operation for 15s, the thermometer will automatically power off.

 

Manual Measurement

 

1. Squeeze and hold the trigger after aiming at the measured object. The SCAN icon will be 

fla

s

hing indicating that the target temperature i

being measured. The measurement result 

will be updated on the LCD.

 

2. Release the trigger

the SCAN icon disappears

and the HOLD icon appears

indicating that 

the measurement has been stopped and the last measured 

v

alue is held

.

 

3. When the measured temperature exceeds 37.2

°

C

the HI icon is displayed, the orange LED 

light is illuminated, and the audible buzzer will sound

.

 

Temperature Unit Setting

 

In the HOLD interface

s

hort pres

the SET button to enter the temperature unit setting interface

and switch between 

°

C and 

°

F by pressing the 

ź

 

button or 

Ÿ

 

button.

 

Audible Alarm Setting

 

In the HOLD interface

short press the SET button twice to enter the audible alarm setting 

interface

and turn on

/

off the audible alarm by pressing the 

ź

 

button or 

Ÿ

 

button

 

Maintenance

 

General Maintenance

 

      

As the thermometer is a reusable instrument

please pay attention to cleaning and maintenance

 

before use. If it is not in use for long periods, please keep the lens clean and dust free.

 

 

1. Clean the case

Wipe dirt 

w

ith a clean soft cloth or cotton s

w

ab dipped in medical alcohol or 

water.

 

2. Clean the lens: Use clean compressed air to blow off loose particles

Carefully wipe the 

surface with a cotton swab dipped in medical alcohol or 

w

ater

.

 

Battery Replacement

 

      

If the thermometer is not in use for a long duration

please

 

remo

v

e the battery to pre

v

ent battery leakage

Dispose of 

used batteries properly in accordance with local regulations.

 

 

To replace the battery

:

 

1. Open the battery cover

.

 

2. Replace with a 9V battery (6F22)

noting the polarity.

 

3. Close the battery cover.

 

 

Troubleshooting

 

 

Symptom

 

Cause

 

Action

 

 

HI appears

 

Measured 

v

alue is greater 

than the maximum range

 

 

Stop measuring

 

 

LO appears

 

Measured value is less 

than the minimum range

 

 

Stop measuring

 

 

Err appears at booting

 

 

Exceeding the minimum or 

maximum operating temperature

 

Place the thermometer in a 

0

°

C- 50

°

C (32

°

F- 122

°

F)

 

environment for 30 minutes

 

Battery symbol flashes

 

Low battery

 

Replace the battery

 

 

 

 

 

    

    

   Product Features

 

•  Bright

easy-to-read

and high-contrast display

 

•  With t

w

o-color (orange and green) LED and buzzer alarm functions

 

• 

W

ith tripod mounting hole (¼ inch)

 

    
   

Di-LOG Ltd

 

Unit 28 Wheel Forge Way 

Trafford Park 

Manchester 

M17 1EH 

UK 

Tel: 0161 877 0322 

Email: 

[email protected]

 

Web: 

www.dilog.co.uk

  

Made in China

Infrared sensor lens

 

Trigger

 

Battery cover

 

Tripod mounting hole

 

LCD display

 

Control Buttons

 

 

Measuring range

 

32

°

C- 42.9

°

C (89.6

°

F - 109.2

°

F)

 

LCD size

 

30mm•3omm

 

LCD display

 

TN LCD

 

Accuracy

 

±0.3

°

C (±0.6

°

F)

 

Optimal measuring distance

 

5cm-10cm

 

Repeatability

 

0.3

°

C (0.6

°

F)

 

Response time

 

250ms (95

of reading)

 

Spectral response

 

8µm-14µm

 

Auto power off

 

15s

 

Lo

battery indication

 

9

 

High temperature LED alarm

 

>

37.2

°

C

orange light alarm (37.2

°

C

green light)

 

High temperature audible alarm

 

>

37.2

°

C: audible alarm

 

Data hold

 

9

 

Unit conversion (

°

C

i° 

F)

 

9

 

Operating environment

 

15

°

C- 30

°

C (59

°

F- 86

°

F)

, <

85% RH

 

Transportation

/

Storage environment

 

-20

°

C- 60

°

C (-4

°

F- 140

°

F)

<85% RH

 

Battery type

 

9V battery (6F22)

 

 

Battery life

 

Continuous temperature measurement: 

•

9 hours for 

the alkaline battery

•

4 hours for the carbon battery

 

Accessories

 

Battery

user manual

 

 

 

 

 

 

 

 

 

 

Отзывы: