DL6780/DL6790 CombiVolt™ 

Voltage & Continuity Indicator

Voltage Indication 12 - 690V 

AC/DC with Continuity

Instruction Manual

EN

61010-1

CAT IV

600V

Содержание CombiVolt DL6780

Страница 1: ...DL6780 DL6790 CombiVolt Voltage Continuity Indicator Voltage Indication 12 690V AC DC with Continuity Instruction Manual EN 61010 1 CAT IV 600V ...

Страница 2: ...V Technical Specification 6 V Display and Controls 7 1 Operating Instructions 7 2 AC Voltage Indication 8 3 DC Voltage Indication 9 4 Single Pole Voltage Indication 10 5 Continuity 11 6 Phase Sequencing Indication 11 12 7 Maintenance 13 8 Battery Replacement 13 9 Calibration 13 10 Accessories 14 11 Warranty Information 14 1 ...

Страница 3: ...aration relates is in conformity with the relevant clauses of the following standards EN 61010 1 2010 EN 61010 2 030 2010 EN 61010 031 2015 EN 61243 3 2014 EN 61326 1 2013 EN 61326 2 2 2013 IEC 60529 IP65 LVD EMC The safety and performance of this instrument is assured when operated within the specifications in this instruction manual The product identified above conforms to the requirements of co...

Страница 4: ...on If this meter is not used in the manner that is specified the protection provided may be impaired Warning Warns of potential danger refer to the instruction manual to avoid personal injury or damage to the meter Caution Dangerous voltage Danger of electrical shock Perfect display is only guaranteed within a temperature range of 10 50 C relative humidity 85 A statement about protection impairmen...

Страница 5: ...heck the test probes for damaged insulation or exposed metal Check the leads for continuity Do not apply more than the rated voltage as marked on the meter between the terminals or between any terminal and ground Do not use or store the meter in an environment of high temperature humidity fumes vapour gaseous inflammable and strong magnetic field The performance and safety of the instrument and th...

Страница 6: ...roduct should not be disposed with other household wastes throughout the EC To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this produc...

Страница 7: ...EN 61010 1 CAT IV 600V DL67xx Voltage Indicator Specification DL6780 DL6790 2 Pole Voltage Indication Voltage range 12 690V AC DC LED resolution 12 24 50 120 230 400 690V LCD resolution n a 1 V 3 8 digits Voltage detection Automatic Frequency range 0 400Hz Peak current 3 5mA Operation time 30 Seconds Acoustic AC DC signal Auto power on 12V AC DC IP rating IP65 Single Pole Indication Voltage range ...

Страница 8: ...rce or approved voltage proving unit If the unit is defective it should be put out of service and returned to Di LOG for repair 7 V Display and Controls 1 Test Probe L1 2 Test Probe L2 3 LED s for voltage indication 4 LED for single pole test 5 Right Left LED phase rotation indication 6 LED for continuity 7 LCD for voltage display only DL6790 8 Contact electrode for double pole test of phase rotat...

Страница 9: ...an AC voltage and a negative DC voltage are indicated The maximum switch on time is 30 s When this time has elapsed you must wait 10 minutes before retesting Connect probes to the voltage source observing the polarity of the test probes L2 is the positive probe L1 is the negative probe For AC voltage the value is indicated on the LEDs 3 and on the LCD display DL6790 only The and LEDs are illuminat...

Страница 10: ...ltage measurement connect probe L2 to the positive terminal and L1 to the negative terminal The voltage is displayed on the LEDs and the LCD display DL6790 only The positive LED 10 is illuminated If the polarity is reversed the buzzer will sound The negative LED 11 will be illuminated 9 ...

Страница 11: ...ole test is intended only as a quick check The circuit must be checked again for the presence of voltage using the two pole method Connect test probe L2 to the voltage source and keep finger on the contact electrode 8 If an AC voltage above 100 V is present the LED 4 is illuminated and the buzzer sounds The single pole test can be negatively affected by unfavourable conditions such as electrostati...

Страница 12: ... only possible when batteries are inserted and in good condition Ensure the circuit under test is not live Connect test probes L1 and L2 to the circuit The continuity LED 6 will illuminate and the buzzer will sound The unit will indicate continuity below 400K ohm 6 Phase Rotation Indication 11 ...

Страница 13: ...correct sequence 1 to 2 Connect test probe L2 to the supposed phase 3 and test probe L1 to the supposed phase2 If the R LED illuminates the phases are in the correct sequence 2 to 3 Connect test probe L2 to the supposed phase 1 and the test probe L1 to the supposed phase 3 If the R LED illuminates the phases are in the correct sequence 3 to 1 During phase rotation test touch the contact electrode ...

Страница 14: ... with a soft damp cloth only Do not use abrasive or chemical cleaning agents 8 Battery Replacement Turn the battery cover by 90 degrees anti clock wise Remove the cover and take out spent batteries Replace with 2 off 1 5 V AAA LR03 batteries checking the correct polarity Replace the battery cover and turn by 90 clock wise Discharged batteries should be disposed of responsibly and with compliance w...

Страница 15: ...ered with and returned to us unopened Damage due to dropping abuse or misuse are not covered by the warranty Product Support support dilog co uk Di LOG Ltd Unit 28 Wheel Forge Way Trafford Park Manchester M17 1EH UK Tel 44 0 161 877 0322 Email sales dilog co uk Website www dilog co uk 14 10 Accessories Spares Optional Accessories TIP780 Replacement GS38 shrouds for probe tip CP1190 CombiVolt Carry...