background image

 

WARNING: 

  Risk  of  Electrocution.  The  probe  tips 

may  not  be  long  enough  to  contact  the  live  parts  inside 

some  240V  outlets  for  appliances  because  the  contacts 

are recessed deep in the outlets. As a result, the reading 

may  show  0  volts  when  the  outlet  actually  has  voltage 

on  it.  Make  sure  the  probe  tips  are  touching  the  metal 

contacts  inside  the  outlet  before  assuming  that  no 

voltage is present. 

 

CAUTION: 

  Do  not  measure  AC  voltages  if  a  motor 

on  the  circuit  is  being  switched  ON  or  OFF.  Large 

voltage surges may occur that can damage the meter. 

1.

 

Set the function switch to the V AC position. 

2.

 

Insert  the  black  test  lead  banana  plug  into  the 

negative (COM) jack and the red test lead banana 

plug into the positive (V) jack. 

3.

 

Touch the test probe tips to the circuit under test. 

4.

 

Read  the  voltage  in  the  display.  The  display  will 

indicate  the  proper  decimal  point,  value  and 

symbol (AC, V, etc.).

 

 

DC CURRENT MEASUREMENTS 

CAUTION: 

  Do  not  make  current  measurements  on 

the 20A scale for longer than 30 seconds. Exceeding 30 

seconds  may cause  damage  to  the  meter  and/or  the  test 

leads. 

1.

 

Insert  the  black  test  lead  banana  plug  into  the  negative 

(COM) jack. 

2.

 

For  current  measurements  up  to  200mA  DC,  set  the 

function  switch  to  the  mA  range  and  insert  the  red  test 

lead banana plug into the (mA) jack. 

3.

 

For  current  measurements  up  to  20A  DC,  set  the 

function  switch  to  the  A  position  and  insert  the  red  test 

lead banana plug into the 20A jack. 

4.

 

Remove power from the circuit under test, then open up 

the  circuit  at  the  point  where  you  wish  to  measure 

current. 

5.

 

Touch the black test probe tip to the negative side of the 

circuit. Touch the red test probe tip to the positive side of 

the circuit. 

6.

 

Apply power to the circuit. 

9.    Read the current in the display. The display will indicate 

the proper decimal point, value.

 

AC CURRENT MEASUREMENTS 

WARNING:

  To  avoid  electric  shock,  do  not  measure 

AC  current  on  any  circuit  whose  voltage exceeds  250V 

AC. 

 

CAUTION: 

  Do  not  make  current  measurements  on 

the 20A scale for longer than 30 seconds. Exceeding 30 

seconds  may cause  damage  to  the  meter  and/or  the  test 

leads. 

1.

 

Insert  the  black  test  lead  banana  plug  into  the  negative 

(COM) jack. 

2.

 

For  current  measurements  up  to  200mA  AC,  set  the 

function  switch  to  the  mA  range  and  insert  the  red  test 

lead banana plug into the (mA) jack. 

3.

 

For current measurements up to 20A AC, set the function 

switch  to  the  A  position  and  insert  the  red  test  lead 

banana plug into the 20A jack. 

4.

 

Remove power from the circuit under test, then open up 

the  circuit  at  the  point  where  you  wish  to  measure 

current. 

5.

 

Touch the black test probe tip to the negative side of the 

circuit.  And  touch  the  red  test  probe  tip  to  the  positive 

side of the circuit. 

6.

 

Apply power to the circuit. 

7.

 

Read  the  current  in  the  display.  The  display  will 

indicate the proper decimal point, value.

 

 

8.

 

RESISTANCE MEASUREMENTS 

WARNING:

 To avoid electric shock, disconnect power 

to the unit under test and discharge all capacitors before 

taking  any  resistance  measurements.  Remove  the 

batteries and unplug the line cords. 

1.

 

Set the function switch to the 

 

 position. 

2.

 

Insert  the  black  test  lead  banana  plug  into  the  negative 

(COM)  jack  and  the  red  test  lead  banana  plug  into  the 

positive 

 jack. 

3.

 

Touch the test probe tips across the circuit or part under 

test. It is best to disconnect one side of the part under test 

so  the  rest  of  the  circuit  will  not  interfere  with  the 

resistance reading. 

4.

 

Read the resistance  in the  display.  The  display  will indicate 

the proper decimal point, value

 

Содержание 9908

Страница 1: ...oltage which exceeds the limits of the multimeter may damage the meter and expose the operator to a shock hazard Always recognize the meter voltage limits as stated on the front of the meter Never apply voltage or current to the meter that exceeds the specified maximum SAFETY SYMBOLS This symbol adjacent to another symbol terminal or operating device indicates that the operator must refer to an ex...

Страница 2: ...oltage drops below the operating level Auto power off Meter automatically shuts down after approx 10 minutes of inactivity Measurement rate 2 times per second nominal Operating environment 0 oC to 50 oC 32 oF to 122 oF at 70 relative humidity Storage temperature 20 oC to 60 oC 4 oF to 140 oF at 80 relative humidity For inside use max height 2000m Pollution degree 2 Power One 9V battery NEDA 1604 I...

Страница 3: ...c or ac rms OPERATION WARNING Risk of electrocution High voltage circuits both AC and DC are very dangerous and should be measured with great care If 1 appears in the display during a measurement the value exceeds the range you have selected Change to a higher range NOTE On some low AC and DC voltage ranges with the test leads not connected to a device the display may show a random changing readin...

Страница 4: ...ositive side of the circuit 6 Apply power to the circuit 9 Read the current in the display The display will indicate the proper decimal point value AC CURRENT MEASUREMENTS WARNING To avoid electric shock do not measure AC current on any circuit whose voltage exceeds 250V AC CAUTION Do not make current measurements on the 20A scale for longer than 30 seconds Exceeding 30 seconds may cause damage to...

Страница 5: ... evaluated as follows A If one reading shows a value and the other reading shows 1 the diode is good B If both readings show 1 the device is open C If both readings are very small or 0 the device is shorted NOTE The value indicated in the display during the diode check is the forward voltage FREQUENCY MEASUREMENT 1 Set the function switch to the 20KHz position 2 Insert the black test lead banana p...

Страница 6: ...ny source of voltage before removing the battery door 1 Disconnect the test leads from the meter 2 Open the battery door by loosening the screw using a Phillips head screwdriver 3 Insert the battery into battery holder observing the correct polarity 4 Put the battery door back in place Secure with the one screw WARNING To avoid electric shock do not operate the meter until the battery door is in p...

Отзывы: