Periodic Maintenance
33
Chapter 3 Maintenance
Care and Maintenance of the Regulator
The regulator is equipped with a filter that becomes filled with drain (moisture and dust) over time. Periodically empty the
drain. If the interior of the bowl becomes soiled, remove and wash the bowl.
Cases Where You Need to Perform this Task
When drain collects
When the bowl is contaminated
WARNING
Before removing the bowl, be sure to bleed off the air pressure.
Failure to do so may cause danger of repute or thrown-off parts.
WARNING
Clean the bowl using a neutral detergent. Never use gasoline, alcohol, thinner, or
any other solvent.
Using a solvent may degrade the bowl and cause danger of rupture.
Empty the Drain
Procedure
Stop the supply of compressed air.
Loosen the lower knob a little at a time.
Material may spray out of the drain at this time. Use a cloth or the like
to catch the spray and keep it from scattering.
When the drain is emptied, retighten the lower
knob.
Lower knob