DFI EC500-CS Скачать руководство пользователя страница 1

EC500-CS

Box PC

User’s Manual

Содержание EC500-CS

Страница 1: ...EC500 CS Box PC User s Manual ...

Страница 2: ... FCC and DOC Statement on Class B This equipment has been tested and found to comply with the limits for a Class B digital de vice pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential instal lation This equipment generates uses and can radiate radio frequency energy and if not in...

Страница 3: ...figuration 22 CSM Configuration 23 USB Power Control 23 Network Stack Configuration 24 Chipset 25 Graphics Configuration 25 PEG Port Configuration 26 PCH IO Configuration 27 PCI Express Configuration 27 SATA And RST Configuration 28 HD Audio Configuration 28 Security 29 Secure Boot 29 Boot 30 Save Exit 30 Updating the BIOS 31 Notice BIOS SPI ROM 31 Chapter 4 Intel AMT Settings 32 Overview 32 Enabl...

Страница 4: ...eplacement or alteration of components and product specifications 2 The warranty is void if the product has been subjected to physical abuse improper in stallation modification accidents or unauthorized repair of the product 3 Unless otherwise instructed in this user s manual the user may not under any circum stances attempt to perform service adjustments or repairs on the product whether in or ou...

Страница 5: ...high temperature surfaces or cause any tripping hazards Do not place anything on top of the power cord Use a power cord that has been ap proved for use with the system and is compliant with the voltage and current ranges required by the system s electrical specifications If the system is to be unused or stored for a long time disconnect it from the power source to avoid damage by transient overvol...

Страница 6: ... 11 OpenCL 2 1 HW Decode HEVC H 265 H 264 M JPEG MPEG2 VC1 WMV9 VP8 8 bit VP9 10 bit HW Encode HEVC H 265 M JPEG MPEG2 VP8 Display Q370 C246 1 x VGA 2 x HDMI DP auto detection H310 1 x VGA 1 x HDMI DP auto detection VGA resolution up to 1920x1200 60Hz HDMI resolution up to 4096x2160 30Hz DP resolution up to 4096x2304 60Hz Dual Triple Displays Q370 C246 1 x VGA 2 x HDMI DP auto detection H310 1 x V...

Страница 7: ...set programmable via software from 1 to 255 seconds SECURITY TPM TPM 2 0 POWER Type Wide range 9 36V Connector 3 pole terminal nlock 3 pin power extension switch connector OS SUPPORT Window Windows 10 IoT Enterprise 64 Bit Linux Linux available upon request MECHANISM Construction Metal Aluminum Mounting Wall Mount Dimensions W x H x D 255 3 x 85 x 224mm Weight 4 15 kg ENVIRONMENT Operating Tempera...

Страница 8: ... USB 3 1 as well as devices based on previous USB versions COM Ports All COM ports can be selected among RS232 RS422 and RS485 HDMI DP VGA Connector Connects the HDMI DP VGA connector of an LCD monitor Line out and Microphone Ports Connect audio devices such as microphones and speakers Gigabit LAN Ports Connect the system to a local area network DC in DC 9 36V power input via a terminal block conn...

Страница 9: ...ow USB 2 0 Ports Connect to USB 2 0 as well as devices based on previous USB versions COM and DIO Ports All COM ports can be selected among RS232 RS422 and RS485 The DIO port provides 8 bit digital input output HDD LED HDD State Disk access activity Disk drives present or not present LED Behavior Blink Off Rear I O Ports Status LED Suspend Mode S0 S1 S3 S4 S5 LED Behavior Always ON Quick Blink cyc...

Страница 10: ...10 Chapter 2 HARDWARE INSTALLATION User s Manual EC500 CS Chapter 2 Hardware Installation Loosen all the screws marked in cyan then tilt up the front cover ...

Страница 11: ...al TS500 Series Remove accessories of HDD Tray memory modules and mini PCIe and M 2 then you can view the top of mainboard If you want to switch to another side please loosen the screws marked in cyan Then switch to another side to install the CPU ...

Страница 12: ...o the slot while making sure 1 the notch and the key are aligned and 2 the non connector end rises approximately 45 degrees horizontally Press the card firmly into the socket while applying and maintaining even pressure on both ends Step 2 Press the end of the card far from the socket down while making sure the retention notch and the clip align as indicated by the dot ted line in the illustration...

Страница 13: ... not require an operating system to run After you power up the system the BIOS message appears on the screen and the memory count begins After the memory test the message Press DEL to run setup will appear on the screen If the message disappears before you respond restart the system or press the Reset button You may also restart the system by pressing the Ctrl Alt and Del keys simultaneously Note ...

Страница 14: ...L2 Cache L3 Cache Number of Processors Microcode Revision Memory RC Version Total Memory Memory Frequency PCH SKU ME FW Version ME Firmware SKU System Date CS263 B19C 12A 07 00 6C 40 07 00 6C 40 0x906EA U0 32 KB x 6 32 KB x 6 256 KB x 6 12 MB 6Core s 12Thread s 9A 0 7 1 111 4096 MB 2400 MHz C246 12 0 55 1521 Corporate SKU Mon 01 07 2020 Advanced The Advanced menu allows you to configure your syste...

Страница 15: ... the hr min sec speci fied RC ACPI Configuration Wake system from S5 via RTC Wake up hour Wake up minute Wake up second State After G3 Enabled 0 0 0 S0 State Advanced Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 America...

Страница 16: ...ows CPU to enter C states when it s idle and nothing is executing Power Limit 1 2 Adjust power limit of the CPU Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc Advanced PCH FW Configuration ME State...

Страница 17: ...General Help F2 Previous Values F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc Advanced AMT Configuration AMT Configuration Secure Erase Configuration Enable Disable of AMT USB Provisioning Change Secure Erase mod ule behavior Simulated Performs SE flow without erasing SSD Real Erase SSD USB Provisioning of AMT Secure Erase Configuration OEM...

Страница 18: ...igure ME Confirmation Prompt Enable or disable to hide unconfigure ME confirmation prompt when attempting ME unconfigu ration Unconfigure ME Enable or disable to unconfigure ME with resetting MEBx password to default Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F9 Optimized Defaults F10 Save Exit E...

Страница 19: ...e None Enables or Disables BIOS support for security de vice O S will not show Security Device TCG EFI protocol and INT1A inter face will not be available Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends...

Страница 20: ...d Enable or Disable Serial Port COM Advanced NCT6116D Super IO Configuration Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc Advanced NCT6116D HW Monitor This section displays the system s health in...

Страница 21: ...perature reaches Boundary 1 setting the fan speed will be turned up to the designated speed of the Fan Speed Count 1 field Fan Speed Count 1 to Fan Speed Count 4 Set the fan speed the value ranging from 1 100 100 being full speed The fans will oper ate according to the specified boundary temperatures above mentioned SYS Smart Fan CPU Smart Fan Control Disabled Fix Fan Speed Count Set the fan speed...

Страница 22: ... Control Select flow control type None or Hardware RTS CTS Flow Control is for RS485 mode and is only supported by Serial Port 1 COM1 Advanced Serial Port Console Redirection Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019...

Страница 23: ...t Change Opt F1 General Help F2 Previous Values F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc Advanced CSM Configuration Advanced Enable Disable CSM Sup port Compatibility Support Module Configuration CSM Support Boot option filter Option ROM execution Network Storage Video Other PCI devices Enabled UEFI only Do not launch UEFI UEFI UEFI Ap...

Страница 24: ...s ESC key to abort the PXE boot Use either or numeric keys to set the value Media detect count Set the number of times the presence of media will be checked Use either or numeric keys to set the value Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F9 Optimized Defaults F10 Save Exit ESC Exit Version ...

Страница 25: ...ized Defaults F10 Save Exit ESC Exit Chipset Version 2 20 1271 Copyright C 2019 American Megatrends Inc Chipset Chipset Graphics Configuration PEG Port Configuration PCI IO Configuration Graphics Configuration Primary Display Select which of IGFX PEG PCI Graphics device to be the primary display Internal Graphics Keep IGFX Enabled or Disabled based on the setup options or select Auto for auto dete...

Страница 26: ...ersion 2 20 1271 Copyright C 2019 American Megatrends Inc Chipset Enable Root Port Enable or disable the root port or select Auto for auto detection Max Link Speed Configure PEG1 PEG3 port s Max Speed Auto Gen1 Gen2 or Gen3 Detect Non Compliance Device Enable or disable this field to detect non compliance PCIe devices in the PEG PEG Port Configuration PEG Port Feature Configuration Enable or Disab...

Страница 27: ...gnment Max TOLUD Enabled Enabled Disabled Dynamic Note The sub menus are detailed in following sections Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F9 Optimized Defaults F10 Save Exit ESC Exit Chipset Version 2 20 1271 Copyright C 2019 American Megatrends Inc Chipset PCH IO Configuration Select on...

Страница 28: ...ation Chipset SATA And RST Configuration SATA Controller s SATA Speed SATA Mode Selection mSATA Port 0 Hot Plug M 2_M Port 1 Hot Plug SATA0 R2 Port 2 Hot Plug SATA1 R3 Port 3 Hot Plug Enabled Auto AHCI Empty Enabled Disabled Empty Enabled Disabled Empty Enabled Disabled Empty Enabled Disabled Enable or disable SATA Device SATA Controller s This field is used to enable or disable the Serial ATA con...

Страница 29: ...ystem mode is User Deployed and CSM is disabled Password Description Minimum length Maximum length Administrator Password Secure Boot System Mode Secure Boot Secure Boot Mode Restore Factory Keys Reset To Setup Mode 3 20 Setup Disabled Not Active Custom Security Secure Boot The Secure Boot store a database of certificates in the firmware and only allows the OSes with authorized signatures to boot ...

Страница 30: ... and Reset Discard Changes and Reset Restore Defaults Boot Override Save Setting to file Restore Setting from file 1 Off Enabled Disabled Save Exit Reset the system after saving the changes Save Changes and Reset To save the changes select this field and then press Enter A dialog box will appear Select Yes to reset the system after saving all changes made Discard Changes and Reset To discard the c...

Страница 31: ...not be removed from this system board and used on another system board of the same model 2 The BIOS SPI ROM on this system board must be the original equipment from the fac tory and cannot be used to replace one which has been utilized on other system boards 3 If you do not follow the methods above the Intel Management Engine will not be up dated and will cease to be effective Note a You can take ...

Страница 32: ... the main menu of the AMI BIOS 2 In the Advanced menu select PCH FW Configuration 3 Set the AMT BIOS Features field to Enabled Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc Advanced When disabled ...

Страница 33: ...rsion 2 20 1271 Copyright C 2019 American Megatrends Inc Advanced Save Options Save Changes and Reset Discard Changes and Reset Restore Defaults Boot Override Save Setting to file Restore Setting from file Reset the system after saving the changes Entering Management Engine BIOS Extension MEBX Version 2 20 1275 Copyright C 2019 American Megatrends Inc BIOS Date 12 12 2019 14 08 56 Ver B19C 12A Pre...

Страница 34: ...ghts Reserved MAIN MENU MEBx Login Intel R ME General Settings Intel R AMT Configuration MEBx Exit Intel R ME Password Move Highlight Enter Select Entry Esc Exit Intel R ME Password MEBX Main Menu Select MEBx Login under Main Menu and press Enter A prompt that requires password input will show up 1 Enter the default password admin Intel R ME General Settings 2 Enter a new password and then press E...

Страница 35: ...en press Enter Intel R Management Engine BIOS Extension v12 0 0 0010 Intel R ME v12 0 55 1521 Copyright C 2003 17 Intel Corporation All Rights Reserved INTEL R ME PLATFORM CONFIGURATION Change ME Password Local FW Update Enabled Intel R ME New Password Move Highlight Enter Select Entry Esc Exit Intel R ME Password Local FW Update Select Local FW Update then press Enter Select Enabled or Disabled o...

Страница 36: ...ght C 2003 17 Intel Corporation All Rights Reserved Manageability Feature Selection Enabled SOL Storage Redirection KVM User Consent Password Policy Anytime Network Setup Activate Network Access Unconfigure Network Access Full Unprovision Remote Setup And Configuration Power Control Disabled Enabled INTEL R AMT CONFIGURATION Move Highlight Enter Complete Entry Esc Discard Changes SOL Storage Redir...

Страница 37: ...r to display options Username and Password Select Enabled or Disabled then press Enter SOL Select Enabled or Disabled then press Enter Storage Redirection Select Enabled or Disabled then press Enter KVM Feature Selection Select Enabled or Disabled then press Enter Intel R Management Engine BIOS Extension v12 0 0 0010 Intel R ME v12 0 55 1521 Copyright C 2003 17 Intel Corporation All Rights Reserve...

Страница 38: ...ation menu select Password Policy then press Enter You may choose to use a password only during setup and configuration or to use a password anytime the system is being accessed Intel R Management Engine BIOS Extension v12 0 0 0010 Intel R ME v12 0 55 1521 Copyright C 2003 17 Intel Corporation All Rights Reserved Manageability Feature Selection Enabled SOL Storage Redirection KVM User Consent Pass...

Страница 39: ...010 Intel R ME v12 0 55 1521 Copyright C 2003 17 Intel Corporation All Rights Reserved Enter Complete Entry Esc Discard Changes INTEL R ME NETWORK NAME SETTINGS Host Name Domain Name Shared Dedicated FQDN Dynamic DNS Update _ _ Shared Disabled Under the Intel R AMT Configuration menu select Network Setup and then press Enter Intel R Management Engine BIOS Extension v12 0 0 0010 Intel R ME v12 0 55...

Страница 40: ... All Rights Reserved INTEL R ME NETWORK NAME SETTINGS Host Name Domain Name Shared Dedicated FQDN Dynamic DNS Update Periodic Update Interval TTL Enter Complete Entry Esc Discard Changes _ _ Shared Enabled 1440 900 Value 0 or 20 1440 Value in Seconds 900 Disabled Enabled Intel R Management Engine BIOS Extension v12 0 0 0010 Intel R ME v12 0 55 1521 Copyright C 2003 17 Intel Corporation All Rights ...

Страница 41: ...0 0 0 0 Preferred DNS Address 0 0 0 0 Alternate DNS Address 0 0 0 0 Enter Complete Entry Esc Discard Changes Subnet Mask Address Insert a value from 0 0 0 0 to 255 255 255 255 in IPv4 format Default Gateway Address Insert a value from 0 0 0 0 to 255 255 255 255 in IPv4 format Preferred DNS Address Insert a value from 0 0 0 0 to 255 255 255 255 in IPv4 format Alternate DNS Address Insert a value fr...

Страница 42: ...RATION Move Highlight Enter Select Entry Esc Exit Manageability Feature Selection Enabled SOL Storage Redirection KVM User Consent Password Policy Anytime Network Setup Activate Network Access Unconfigure Network Access Full Unprovision Remote Setup And Configuration Power Control Activates the current network settings and opens the ME network interface Continue Y N Intel R Management Engine BIOS ...

Страница 43: ...he current mode Public Key Infrastructure PKI is displayed Intel R Management Engine BIOS Extension v12 0 0 0010 Intel R ME v12 0 55 1521 Copyright C 2003 17 Intel Corporation All Rights Reserved Move Highlight Enter Select Entry Esc Exit INTEL R REMOTE SETUP AND CONFIGURATION Current Provisioning Mode Provisioning Record Provisioning Server IPV4 IPV6 _ Provisioning Server FQDN _ RCFG TLS PKI Prov...

Страница 44: ... encryption and authentication and the TLS protocol for communica tion security to ensure remote configuration safety Remote Configuration Select Enabled or Disabled then press Enter Intel R Management Engine BIOS Extension v12 0 0 0010 Intel R ME v12 0 55 1521 Copyright C 2003 17 Intel Corporation All Rights Reserved INTEL R REMOTE CONFIGURATION Remote Configuration Enabled PKI DNS Suffix _ Manag...

Страница 45: ...Default Default Default Default Default Default Default Default Default Default Default Default SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 Hash Name Active Default Algorithm VeriSign Class 3 VeriSign Class 3 Go Daddy Class 2 Comodo AAA CA Starfield Class 2 VeriSign Class 3 VeriSign Class 3 VeriSign Class 3 GTE Cyber...

Страница 46: ... Y to confirm or N to abort Intel R Management Engine BIOS Extension v12 0 0 0010 Intel R ME v12 0 55 1521 Copyright C 2003 17 Intel Corporation All Rights Reserved MAIN MENU Move Highlight Enter Select Entry Esc Exit Are you sure you want to exit Y N Intel R ME General Settings Intel R AMT Configuration MEBx Exit Exit MEBX ...

Страница 47: ...ding the benefits of both RAID 0 and RAID 1 Use four new drives or an existing drive and three new drives for this con figuration RAID Level Min Drives Protection Description RAID 0 2 None Data striping without redundancy RAID 1 2 Single Drive Failure Disk mirroring RAID 5 3 Single Drive Failure Block level data striping with distributed parity RAID 10 4 1 Disk Per Mirrored Stripe not same mirror ...

Страница 48: ...to select the RAID level and press Enter 4 Use the up or down arrow keys to scroll through the list of hard drives and press En ter to select the drive 5 Press Enter 6 Use the up or down arrow keys to select the strip size and press Enter 7 Enter the volume size and press Enter 8 At the prompt press Y to confirm volume creation Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Sc...