DFE TRUETENSION TA1 Скачать руководство пользователя страница 1

INSTRUCTION MANUAL

 

T

RUE

T

ENSION

TM

 

Model TA1

 

Tension Amplifier

DOC 801-2568

 R2

Содержание TRUETENSION TA1

Страница 1: ...INSTRUCTION MANUAL TRUETENSIONTM Model TA1 Tension Amplifier DOC 801 2568 R2...

Страница 2: ...cing orders for standard products and special systems Please mailto sales dfe com call 603 332 6150 and ask for Sales or email to us at sales dfe com Telephone 603 332 6150 Fax 603 332 3758 E mail inf...

Страница 3: ...Email techsupport dfe com Telephone 603 332 6150 Observe all warning labels Never remove warning labels WARNING If this equipment is not connected or operated in the manner specified the operating sa...

Страница 4: ...Troubleshooting 8 APPENDIX A Transducer Connections 9 Terms and Conditions 11 Figures 1 Dimensions 2 2 Removing From DIN Rail 2 3 Convert to Screw Mount 3 4 Power Input Connections 3 5 Tension Output...

Страница 5: ...sion Outputs Output 1 0 10 VDC isolated from 24 VDC input GND Output 2 4 20 mA isolated from 24 VDC input GND Calibration Range Up to 50 1 Processor 32 Bit Weight 0 25 lbs 114g Resolutions ADC 16 777...

Страница 6: ...N 2 1 Dimensions 2 2 Mounting the Unit The unit is DIN rail mountable compatible with DIN35mm rail Snap on to mount To remove from the DIN rail use a screwdriver and release the clamp as shown below F...

Страница 7: ...Standard Electrical Connections 1 Power Input Power should be sourced to the TA1 on Pins 1 GND and 2 24 VDC FIGURE 4 Power Input Connections 2 Tension Output The tension output signal is provided in...

Страница 8: ...2 3 Standard Electrical Connections continued 3 Transducers Load Cells FIGURE 6 Transducer Electrical Connections See Appendix A for full Electrical Connections Below is label on left side of unit 4...

Страница 9: ...tion the 24V must be applied to PIN 6 A switch can be used as shown below If a PLC or alternate source for 24V is utilized be sure that the source has a common Ground with PIN 1 If you do not need dua...

Страница 10: ...the unit front panel for at least 1 second The unit will automatically adjust and store the tension zero value one second after the button is pressed The unit will rapid flash the green status LED to...

Страница 11: ...5 Push and Hold Cal Button About 10 Seconds until you see two sets of confirmation blinks Then release the button The output will read 25 of full scale after calibration If no blink inadequate Cal wei...

Страница 12: ...0 or 120 tension is exceeded Action Required To clear this error the tension must be brought back into range or a new calibration will need to be performed to do so 3 Blinks Wiring Error Will alert un...

Страница 13: ...FIGURE 11 Electrical Connections for Models C F Transducers APPENDIX A Transducer Connections 9...

Страница 14: ...APPENDIX A Transducer Connections continued Figure 12 Electrical Connections for NW RFA TR LT VNW Transducers 10...

Страница 15: ...d terms or the terms originally specified the Company may require full or partial payment in advance or upon delivery The Company reserves the right to make col lection on any terms approved in writin...

Страница 16: ...630 U S A TEL 603 332 6150 FAX 603 332 3758 E mail info dfe com Internet www dfe com CANADA MEXICO UNITED KINGDOM TAIWAN KOREA CHINA INDIA AUSTRALIA SOUTH AFRICA 2021 DOVER FLEXO ELECTRONICS INC ALL R...

Отзывы: