- 13 -
3.5.1 PV Module Selec�on:
3.5.2 PV Module Wire Connec�on:
When selec�ng proper PV modules, please be sure to consider below parameters:
1) Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of
inverter.
2) Open circuit Voltage (Voc) of PV modules should be higher than min. start voltage.
Please follow below steps to implement PV module connec�on:
1. Remove insula�on sleeve 10 mm for posi�ve and nega�ve conductors.
2. Suggest to put bootlace ferrules on the end of posi�ve and nega�ve wires with a proper
crimping tool.
3. Check correct polarity of wire connec�on from PV modules and PV input connectors. Then,
connect posi�ve pole (+) of connec�on wire to posi�ve pole (+) of PV input connector. Connect
nega�ve pole (-) of connec�on wire to nega�ve pole(-)of PV input connector. Close the switch
and make sure the wires are �ghtly fixed.
Chart 3-5
PV Input Voltage
Inverter Model
6KW
5KW
7.6KW
8KW
370V (100V~500V)
125V-425V
PV Array MPPT Voltage Range
No. of MPP Trackers
No. of Strings per MPP Tracker
2
2+1
1+1
2+2