Error code
Description
Ongrid - Three Phase
F01
DC input polarity reverse fault
Check the PV in put polarity
.
F03
DC leakage current fault
Hardly appear the code. Never ever happened so far
.
F07
GFDI blown fuse
Hardly appear the code. Never ever happened so far
.
F11
AC main contactor errors
Hardly appear the code. Never ever happened so far
.
F12
AC auxiliary contactor errors
Hardly appear the code. Never ever happened so far
.
F14
DC firmware over current
Hardly appear the code. Never ever happened so far.
F08
GFDI grounding touch failure
Hardly appear the code. Never ever happened so far
.
F02
DC insula�on impedance
permanent fault
Check the grounding cable of inverter.
F04
Ground fault GFDI
Check the solar panel output connec�on.
F17
Hardly appear the code. Never ever happened so far.
F09
IGBT damaged by excessive drop
voltage
Hardly appear the code. Never ever happened so far.
F10
Auxiliary switch power supply
failure
F05
Read the memory error
Failure in reading memory (EEPROM). Restart the inverter if the
fault s�ll exists, contact your installer or Deye service.
F06
Write the memory error
Failure in wri�ng memory (EEPROM). Restart the inverter if the
fault s�ll exists, contact your installer or Deye service.
1. It tells the DC 12V is not existed.
2. Restart the inverter, if the fault s�ll exists, please contact y
our installer.
F13
Working mode changed/Grid
mode changed
1. Lost of one phase or AC voltage detec�on circuit or relays not
closed (old inverter not have relays detec�on func�on).
2.
Restart the inverter, if the error s�ll exists, please contact your
installer or Deye service.
F20
DC over current fault of the
hardware
1. Check whether solar panel output current is within the
allowed range.
2. Check DC current sensor and its detec�on circuit.
3. Check if the inverter FW version is suitable for the hardware.
4.
Restart the inverter, if the error s�ll exists, please contact your
installer or Deye service.
F15
AC firmware over current
1. The internal AC sensor or detec�on circuit on control board
or connec�on wire may loose.
2. Restart the inverter, if the error s�ll exists, please contact
your installer or Deye service.
F18
AC over current fault of hardware
1. Check AC sensor or detec�on circuit on control board or
connec�on wire.
2. Restart the inverter or factory reset, if the error s�ll exists,
please contact your installer or Deye service.
F16
GFCI(RCD) Ac leakage current
fault
1. This fault means the average leakage current is over 300mA.
Check whether DC power supply or solar panels is ok, then
check 'Test data'-> 'diL'value is about 40; Then check the
leakage current sensor or circuit (the following picture).
Checking test data needs using big LCD.
2.
Restart the inverter, if the error s�ll exists, please contact your
installer or Deye service.
Three phase current,
over-current fault
F19
Hardly appear the code. Never ever happened so far.
All hardware failure synthesis