5.9 Generator Port Use Setup Menu
5.10 Advanced Function Setup Menu
Mode
OFF
ON
Generator Input
SmartLoad Output
Micro Inv Input
Gen connect to Grid input
On Grid always on
Ml export to Grid cutoff
GEN PORT USE
60Min
100%
95%
Power
Open Delay
1000W
PORT
Set1
Clear Arc_Fault
Solar Arc Fault ON
System selfcheck
Gen peak-shaving
Power
7000W
Grid peak-shaving
Power
4000W
Advanced Function
Func
Set1
DC1 for WindTurbine
V1
V2
V3
V4
V5
V6
V7
V8
V9
V10
V11
V12
0V
0V
0V
0V
0V
0V
0.0A
0.0A
0.0A
0.0A
0.0A
0.0A
0V
0V
0V
0V
0V
0V
0.0A
0.0A
0.0A
0.0A
0.0A
0.0A
DC1 for WindTurbine
Advanced Function
Wind
Set2
This is for Wind Turbine
Gen Peak-shaving---Enable When the power of the
generator exceeds the rated value of it, the inverter will
provide the redundant part to ensure that the generator
will not overload.
Grid Peak-shaving---Enable When the power of the grid
exceeds the set value, the inverter will provide the
redundant part to ensure that the grid power does not
exceed the set value.
System selfcheck ---Disable. this is only for factory.
Solar Arc Fault ON---This is only for US.
Generator Input:use Generator
SmartLoad Output: if the SOC is up than
“ON”and solar power is high than 1000W.
the inverter will open smartload.
On Grid always on:mean when have Grid,the
smartload will always on
Micro Inv Input:Inverter will open
Microinverter.if the SOC is below the“ON”
and close if the SOC is up than the“OFF”
- 29 -
- 30 -
6. Mode
5.11 Device Info Setup Menu
Factory Reset: 9999
HMI: LCD version
PassWord
DEL
X--X--X--X
1
2
3
4
5
6
7
8
9
CANCEL
0
OK
Volt
1
2
3
50.38V 19.70A
30.6C
52.0%
26.0Ah
0.0V
0.0A
0|0|0
50.33V 19.10A
31.0C
51.0%
25.5Ah
53.2V
25.0A 0|0|0
50.30V 16.90A
30.2C
12.0%
6.0Ah
53.2V
25.0A 0|0|0
4
5
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
6
7
8
9
10
11
12
13
14
15
Curr
Volt
Curr
Temp
SOC
Energy
Charge
Fault
Sum
Data
Details
Data
Li-BMS
Volt
1
2
3
50.38V 19.70A
30.6C
52.0%
26.0Ah
0.0V
0.0A
0|0|0
50.33V 19.10A
31.0C
51.0%
25.5Ah
53.2V
25.0A 0|0|0
50.30V 16.90A
30.2C
12.0%
6.0Ah
53.2V
25.0A 0|0|0
4
5
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
0.00V
0.00A
0.0C
0.0%
0.0Ah
0.0V
0.0A
0|0|0
6
7
8
9
10
11
12
13
14
15
Curr
Volt
Curr
Temp
SOC
Energy
Charge
Fault
Sum
Data
Details
Data
Li-BMS
Device Info.
Inverter ID: 1601012001
MAIN:Ver1400
HMI: Ver0302
Alarms Code
F64 Heatsink_HighTemp_Fault
F64 Heatsink_HighTemp_Fault
F64 Heatsink_HighTemp_Fault
2019-03-11 15:56
2019-03-08 10:46
2019-03-08 10:45
Occurred
Device
Info
3UJK/ (GYOI
MAIN: MCU version
This page show Inverter ID, Inverter version
and alarm codes.
Lock out all changes:7777
Grid
Backup Load
On-Grid Home Load
CT
Battery
Solar
AC cable
DC cable
COM cable