5.1 Main Screen
5. LCD Display Icons
The LCD is touchscreen,below screen shows the overall information of the inverter.
1.The icon in the center of the home screen indicates that the system is Normal operation.
If it turns into “comm./F01~F64” ,it means the inverter has communication errors or
other errors,the error message will display under this icon(F01-F64 errors,detail error info
can be viewed in the System Alarms menu).
2.At the top of the screen is the time.
3.System Setup Icon,Press this set button,you can enter into the system setup screen which
including Basic Setup,Battery Setup,Grid Setup,System Work Mode,Generator port use,
Advanced function and Li-Batt info.
4.The main screen showing the info including Solar,Grid,Load and Battery.Its also
displaying the energy flow direction by arrow.When the power is approximate to high level,
the color on the panels will changing from green to red so system info showing vividly on
the main screen.
· PV power and Load power always keep positive.
· Grid power negative means sell to grid,positive means get from grid.
· Battery power negative means charge,positive means discharge.
25%
05/28/2019 15:34:40
8.30
KW
-2.00
KW
-3.00
KW
3.00
KW
0
12
0
8
0
8
0
8
54
5.1.1 LCD operation flow chart
Main Screen
Solar Page
Solar Graph
Grid Graph
BMS Page
Load Graph
Battery Setting
System Work Mode
Grid Setting
Gen Port Use
Basic Setting
Advanced Function
Device info
Grid Page
Inverter Page
Battery Page
Load Page
System Setup
- 21 -
- 22 -