ENGLISH

LANGUAGE

MANUAL

FS-875

FS-3875

Bath Fan Timer Control

with Light Control

ADJUSTABLE

FAN TIMER

 (D.) MOUNTING IN WALL ENCLOSURE

  1. 

Attach wires (as shown in FIGURE #1).

WARNING

Turn OFF circuit breaker or remove fuse(s) and test 

that power is OFF before wiring. Wiring this control 

live can cause serious risk of electrical shock 

and/or damage the control, voiding the warranty. 

FOR SAFETY, THIS PRODUCT MUST BE 

INSTALLED IN A GROUNDED WALL ENCLOSURE. If 

you are unfamiliar with methods of installing 

electrical wiring, secure the services of a qualified 

licensed electrician. USE ONLY COPPER WIRE, DO 

NOT use aluminum wire with this device.

IMPORTANT

Read each step carefully and perform in sequence. 

This control will not work or will become damaged 

if wires are connected incorrectly. To prevent 

damage, connect this control exactly as shown in 

the installation diagrams, otherwise warranty will 

be voided. Prior to wiring, straighten or clip ends of 

wire such that ends of each wire are straight (if 

using this control to replace an existing switch). 

Strip wire insulation at the end of each wire to 

expose 5/8 inch (16 mm) of copper. Where 

instructed to make a connection, twist ends of 

stripped wires together and twist a proper 

connector clockwise until secure.

 (C.) INSTALLATION STEPS

  

1. WARNING

      To avoid fire or risk of electrical shock, turn OFF 

      power at circuit breaker or disconnect fuse. Test the 

      power is OFF before you begin wiring.

  2. BEFORE YOU MOUNT THE CONTROL 

      (new installation) Install control in a 3½ inch deep 

      single-gang or multi-gang electrical wall enclosure. 

      OR (replacement of existing switch) remove 

      existing wall plate and switch device being 

      replaced.

  3. ATTACH POWER WIRE, LIGHT WIRE, AND 

      FAN WIRE

      Attach 120V AC 60Hz 3-wire power (Hot / Neutral / 

      Ground) inside the wall enclosure with a minimum 

      of 6 inch leads. Attach fan three wire leads inside 

      the wall enclosure also with minimum 6 inch leads.  

      If an existing power connection is used in an 

      existing wall enclosure you must confirm proper AC 

      120V Hot / Neutral / Ground are available.

  4. CONNECT WIRING

      General instructions for all configurations:

      Make sure the wall enclosure, fan, light, and 

      control are properly grounded. (See FIGURE #1).
Make sure ground wire is securely fastened. Tighten all 

ground screws or wire nuts securely. Use the proper 

sized wire nut for #14 or #12 wire. Make sure to strip 

back the copper wire 5/8 inch and twist wire and 

nut clockwise.

 (A.) ABOUT

This timer is designed to give you all the options, all the 

control you need, to make sure your bathroom, laundry 

room, sun room, or spa room gets all the ventilation it 

should have. It's really two timers in one: A countdown timer 

and a fresh home / Minutes Per Hour (MPH) timer ‒ and, 

best of all, the two timers work together. The countdown 

timer can be set anywhere from 5 to 60 minutes, and it 

activates any time you manually turn the fan on. The MPH 

timer can be set to anywhere from 0 to 60 minutes, and it 

runs your fan for a set time every hour to expel stale air and 

help you maintain good indoor air quality (just the thing for 

complying with local indoor air quality standards, such as 

ASHRAE 62.2). The MPH timer also sees when you've 

used the countdown timer and knows not to run the fan for 

a while if you've already done it. If you want to manually 

shut the fan off when the MPH timer is running, you can do 

that too, just by pressing the fan on/off button.

 (B.) INSTALLATION INSTRUCTIONS

CAUTION

  1. Use only a 120V AC 60Hz power supply  

      connection.

  2. For indoor use only.

  3. Do not exceed this control’s maximum electrical 

      load ratings, as indicated on the product label.

  4. Must be installed and used in accordance with 

      your local electrical codes.

  5. If a bare copper or green ground connection is 

      not available in the wall box, contact a 

      licensed electrician for installation.

  6. For use with permanently installed 120V AC 

      powered fans only.

  7. Use only #14 or #12 copper wire connections.

  3. Attach the wall plate (See FIGURE #3).

  2. Tuck wires into wall enclosure and fasten control to 

      the wall enclosure with the two screws provided 

      (See FIGURE #2).