main SyStem
12
Main system
Key facts
`
Rugged industrial design
`
4 slots for TRION/TRION3 acquisition series modules
`
Up to 32 analog highspeed inputs
`
Optional internal buffer battery for <5 minutes
`
Local data storage or data transfer via Ethernet
System specifications
DEWE3-M4
Input channels
Up to 32 analog highspeed inputs
Input specification
Supports all TRION/TRION3 (highspeed) series interface modules.
Optimized to operate with highspeed TRION3 series modules.
Open slots for TRION/TRION3 modules
4
Features
–
1 programmable frequency output 10 to 1,000,000 Hz)
–
2 advanced counter input, 2 basic counter
–
8 digital inputs, 4 digital outputs
High-speed channel expansion
Add TRIONet at any time by SYNC interfaces or other instruments via
OXYGEN-NET
Low-speed channel expansion (100 Hz)
CPAD3 via TRION-CAN
Quasi-static channel expansion
EPAD2 interface connector, CPAD2 via TRION-CAN
MBTF
31,312 h
Main system
System bandwidth
400 MB/s
Data storage
1 TB SSD dedicated for data storage (400 MB/s)
256 GB SSD for operating system and application software
Power supply input
–
Rated input voltage
–
DW2-PS-PC-BUFFER (optional)
11...32 V
DC
(max. 10...36 V
DC
), 210 W isolated, external AC power supply
included
Internal UPS battery for <5 min. (dep. on system and configuration)
Power consumption incl. modules
Typ. 150 W (depending on installed TRION/TRION3 series modules)
Cooling capacity
25 W per module slot
Dimensions (W x D x H) without feet
317 x 253 x 124 mm (12.5 x 10 x 4.9 in.)
Weight w/o TRION modules
Typ. 6 kg (13.22 lbs)
Environmental specifications
Operating temperature
0 °C to +50 °C, down to -20 °C with pre-warmed unit
Storage temperature
-20 °C to +70 °C
Humidity
10 % to 80 %, non condensing; 5 % to 95 % rel. humidity
Altitude
1)
4000 m (13,123 ft.)
Tab. 1: System specifications DEWE3-M4