SAFETY INSTRUCTIONS

Your safety is our primary concern! Please be safe!
 

        

 

> Use this system under the terms of the specifications only to avoid any possible danger. If the unit is used 

  in a manner not specified by the manufacturer the protection can be impaired!

 

> Ths product is intended for use in industrial locations. As a result, this product may cause interference    

 

  if used in residential areas. Such use must be avoided unless the user takes special measures to reduce 

  electromagnetic emissions to prevent interferences to the reception of radio and television broadcasts.

 

> Maintenance will be executed by qualified staff only.

 

> During the use of the system, it might be possible to access another parts of a more comprehensive    

 

  system. Please read and follow the safety instructions provided in the manuals of all other components  

 

  regarding warning and security advices for using the system.

 

> With this product, only use the power cable delivered or defined for the host country.

 

> DO NOT connect or disconnect sensors, probes or test leads, as these parts are connected to a voltage   

 

  supply unit.

 

> The system is grounded via a protective conductor in the power supply cord. To avoid electric shocks,    

 

  the protective conductor has to be connected with the ground of the power network. Before connecting the input  

  or output connectors of the system, make sure that there is a proper grounding to guarantee 

  potential free usage. For countries, in which there is no proper grounding, please refere to your local    

 

  legally safety regulations for safety use.

  DC systems: Every DC system has a grounding connected to the chassis (yellow/green safety banana    

 

  plug).

 

> Please note the characteristics and indicators on the system to avoid fire or electric shocks. Before  

 

 

  connecting the system, please carefully read the corresponding specifications in the product manual.

 

> The inputs are not, unless otherwise noted (CATx identification), for connecting to the main circuits of    

 

  category II, III and IV. The measurement category can be adjusted depending on module configuration.

 

> The power cord separates the system from the power supply. Do not block the power cord, since it has to  

 

  be accessible for the users.

 

> Supply overvoltage category is II.

 

> DO NOT use the system if equipment covers or shields are removed.

 

> If you assume the system is damaged, get it examined by authorised personnel only. 

 

> Any use in wet rooms, outdoors or in adverse environmental condition is not allowed! 

  Adverse environmental conditions are:

  >  Moisture or high humidity 

  >  Dust, flammable gases, fumes or dissolver 

  >  Thunderstorm or thunderstorm conditions (except assembly PNA) 

  >  Electrostatic fields, et cetera.

 

> Any direct voltage output is protected with a fuse against short cut and reverse-polarity, but is NOT  

 

 

  galvanically isolated (except it is explicit marked on the system).

 

> The system must be connected and operated to an earthed wall socket at the AC mains power supply    

 

  only (except for DC systems).

 

> Any other use than described above may damage your system and is attended with dangers like shortcut,  

 

  fire or electric shocks.

!

General safety and hazard warnings for all DEWETRON systems

Содержание DEWE2-PA7

Страница 1: ...th accurate complete and reproducible measurement results for your decision making Look forward to the easy handling and the flexible and modular use of your DEWETRON product and draw upon more than 2...

Страница 2: ...t All rights are reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws All trademarks and registered trademarks are...

Страница 3: ...artup notes as well as safety notes and information about keeping your DEWETRON system in good working condition over time We strongly suggest that you read this entire manual especially the safety an...

Страница 4: ...4 PREFACE Notes...

Страница 5: ...ware 14 Problematic network stacks 14 Environmental Considerations 14 Main System 15 DEWE2 PA7 at a glance 15 Configuration examples with TRION 1820 POWER module 18 Application examples 20 Installing...

Страница 6: ...6 TABLE OF CONTENT...

Страница 7: ...on system are available for purchase with each order We retain them for at least one year so calibration reports can be purchased for up to one year after your system was delivered Support DEWETRON ha...

Страница 8: ...of the information in this document Warranty Information A copy of the specific warranty terms applicable to your DEWETRON product and replacement parts can be obtained from your local sales and serv...

Страница 9: ...ntion to a procedure practice or condition that could cause bodily injury or death CAUTION Calls attention to a procedure practice or condition that could possibly cause damage to equipment or permane...

Страница 10: ...grounding please refere to your local legally safety regulations for safety use DC systems Every DC system has a grounding connected to the chassis yellow green safety banana plug Please note the cha...

Страница 11: ...ilous electric shock by touching the wiring Unless otherwise stated maximum input voltage for measuring cards are 70 VDC and 46 7 VPEAK The product heats during operation Make sure there is adequate v...

Страница 12: ...ft the factory in safety related flawless and proper condition In order to maintain this condition and guarantee safety use the user has to consider the security advices and warnings in this manual EN...

Страница 13: ...erior and exchange filter foam based on the operating environment Cleaning Clean surface of the chassis with dry lintfree cloth Use a dry velocity stream of air to clean the chassis interior Disconnec...

Страница 14: ...mary function of the DEWETRON system to record data Therefore we recommend strongly against the installation of IT MIS software and running their processes on any DEWETRON data acquisition system and...

Страница 15: ...terface connector 2 USB 3 0 interface connectors 3 USB 2 0 interface connectors 4 Power on off switch 5 Chassis terminal 6 TRION series module slots 7 Power supply connectors for current clamps 8 9 mu...

Страница 16: ...ts it s necessary to provide the system with an additional ground connection 6 TRION series module slots 7x slots for TRION series modules The DEWE2 PA7 supports all modules 7 Power supply connectors...

Страница 17: ...nector meets standard DVI pin assignment 16 RS 232 interface connectors COM1 COM2 The RS 232 interface connectors male are located on the left side of the DEWE2 A4L They are configured as standard RS...

Страница 18: ...0 POWER module Standard 4 phase power analyzer with direct input This is the standard configuration of a DEWE2 PA7 for 4 phase 1x 3 phase AC and 1x 1 phase DC applications Standard 4 phase power analy...

Страница 19: ...ge and acceleration analysis Absolute time synchronization option With this option the power analyzer can operate synchronized with other measurement devices with an absolute time reference 1 x DEWE2...

Страница 20: ...ted Clock detected Receiving clock GREEN stable Acquisition running Acquisition running Depending on the usage of the SYNC I O input or output the LED indicates if the system clock is available or rec...

Страница 21: ...modules require a TRION STAR slot Step 4 Remove the filler panel of an unused TRION peripheral or STAR slot Step 5 Place the module edges of the TRION modules into the module guides at the top and bot...

Страница 22: ...tap Similar to clicking with a mouse Pinch or stretch How to do it Touch the screen with two fingers and then move the fingers toward each other pinch or away from each other stretch What it does Zoom...

Страница 23: ...idth 5 MHz Safety CAT IV 600 V CAT III 1000 V Instantaneous maximum allowable input 4000 VPEAK or 3000 VRMS 1s Continuous maximum allowable input 2000 VRMS Input resistance 5 M 2 pF Isolation earth re...

Страница 24: ...ci cations Typical power accuracy with direct current input 45 Hz to 1 kHz 0 02 of reading 0 02 of range Typical channel to channel phase mismatch Voltage Voltage Current Current Voltage Current 50 ns...

Страница 25: ...n 9 9 V 40 mA max WARNING This module is not isolated Do not connect any other appliances than isolated current transducers with voltage output Exchanging current modules 1 Switch off the instrument a...

Страница 26: ...h the torx screw M2x4 TX6 Max torque 0 2 Nm 6 Insert the TRION 1820 POWER 4 module into the housing until a resistance appears 7 Pull up the injector ejector handle to latch the module Tighten the scr...

Страница 27: ...andwidth and minimum capacity to earth are just a few outstanding performance qualities of the high voltage inputs The high input impedance allowes high continous voltage levels with a very low temper...

Страница 28: ...130 TRION 1820 POWER 4 Connection examples Three phase 3P3W without neutral line Group selection in OXYGEN Power Group selection in OXYGEN Power Three phase 3P3W without neutral line using current out...

Страница 29: ...YSTEM 131 TRION 1820 POWER 4 TRION series modules Technical Reference Manual Printing version 1 2 5 February 12 2017 Group selection in OXYGEN Power Group selection in OXYGEN Power Three phase 3P3W wi...

Страница 30: ...30 MAIN SYSTEM 132 Group selection in OXYGEN Power Group selection in OXYGEN Power One phase 1P2W Three phase and one phase 3P3W and 1P2W...

Страница 31: ...1 x RS232 2 x PS 2 2 x display port AUDIO interface 64 bit Microsoft Windows 10 operating system incl 64 bit OXYGEN data acquisition software Data storage 1 TB HDD dedicated for data storage upgrade t...

Страница 32: ...input voltage Input frequency Max input current 100 to 240 VAC max 90 to 264 VAC active PFC 47 to 63 Hz 7 A 115 VAC 3 5 A 230 VAC Output Output power Output voltages max 400 W 3 3 V max 28 A 5 V max...

Страница 33: ...t more than 4x PA IT 1000 can be supplied in the absolute worst case due to the concurrency factor of the applied power system The following applications can be met selection with nominal current due...

Страница 34: ...To clean the filter pad use a dry velocity stream of air Afterwards make sure to reinstall the louver and filter pad Installing the optional 19 mounting kit M5x8 M5x8 Left assembly bracket Right asse...

Страница 35: ...ower supply as well as the modules plugged into the chassis NOTE When installing the DEWE2 PA7 into a 19 cabinet please keep in mind that the unit is siphoning air from the bottom see schematic above...

Страница 36: ...36 177 465 15 18 387 18 427 3 440 8 65 110 167 21 34 277 MAIN SYSTEM Dimensions Dimensions in mm 1 inch 25 4 mm...

Страница 37: ...directives 2014 35 EU Directive of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market o...

Страница 38: ...C2 NOTES...