2.7 CAN interface
As an option the DEWE-ORION-1616-10x also can be suited with two high speed CAN interfaces. Both ports
are compatible with CAN 2.0B specification. The CAN transceiver (TI SN65HVD235) has a bus-pin fault
protection of up to ±36 V.
The main application for these CAN-ports is acquiring CAN data together with analog data. Although the
CAN data is asynchronous to the analog data, the DEWE-ORION-1616-10x series guarantees perfect
synchronization. Each incoming CAN message is directly time stamped to the analog sample count number
before the data is transferred to the application software.
If just CAN acquisition of CAN messages is required the “Listen Only” mode can be used. In this mode the
DEWE-ORION-1616-10x board generates no output data even if the CAN-baud-rate is wrong selected. But
this mode is not working using just a direct connection to a sensor. In a point-to-point connection the “Listen
Only” mode has to be deactivated at the CAN-Interface. The setup in DEWESoft is shown in the screenshot
on the next page.
CAN setup in DEWESoft
2.8 RS-485 interface
The DEWE-ORION-1616-10x is suited with an RS-485 interfaced as standard. The baud-rate is fixed to
9600, 8 Data, 1 Stop bit and no parity. This interface is used for configuration of the DAQ and MDAQ signal
conditioning modules. Also the acquiring of PAD and EPAD from DEWETRON is possible with this RS-485
port. The interface of the main board and the expansion boards (DEWE-ORION-1616-102 with counter ex-
pansion) is controlled separately.