Dewetron DEWE-50-USB2-16-NI Скачать руководство пользователя страница 13

B1

1 2 3 4 5

6 7 8 9

W2

W3

W4

W6

W7

W1

W8

W9

W10

W11

W5

W1

W2

W3

W4

W5

W6

W7

W8

W9

W10

W11

CH 1 

CH 2 

CH 3 

CH 4 

CH 5 

CH 6 

CH 7 

CH 8 

CH 9 

CH 10 

CH 11 

CH 12 

CH 13 

CH 14 

CH 15 

USB

DM 

DP

 

GND

C

 

RX

 

TX

RS-485

GND

C

 

B

 

B

 

POWER

+V

 

+12  V

 

GND

P

 

-12 V 

-V 

A (RS-485)

 

GND

C

 

B (RS-485)

 

GND

P

 

+V

 

+12 V

 

-12 V 

-V

GND

C

 

GND

C

 

TX

 

RX

GND

POWER

RS-485

RS-232

RES

GND

Indicator

 

+9 V

 

-9 V

CH 0 

GND

 

DE-M071203E • DEWE-50-USB2-16-NI • Technical Reference Manual • Printing version 1.0.0 • Dec. 17, 2007

Internal Wiring

16 slot DEWE-MOTHERBOARD DAQ-MOTH-16-DE-x

Internal Wiring

Front view

Rear view

9-pin SUB-D pin assignment:

1  Module input (±5 V)

 

2  RS-485 (A)

 

3  RS-485 (B)

 

4  GND 

5  +9 V power supply

 

6  +12 V power (default) /

 

 

+V sensor supply

 

7  Module output 

 

(from A/D board)

 

8  -V sensor supply 

9  -9 V power supply

The 16 slot DEWE-MOTHERBOARD receives the ±12 V

DC

 power supply via a DC/DC converter from the 

internal power supply.

5 V ORION

 

Ext. CLK

 

Ext. TRIG

 

DGND ORION

 

Ext. CLK 2 OUT

 

Ext. CLK 1 OUT

 (CAMERA TRIGGER) 

 

 

DGND ORION

 

16x GND

16 x analog OUT (resistance 50 Ohm)

GND 

+15 V ORION

 

-15 V ORION

 

 

16 channels single ended

 

analog output 

(output resistance 15 Ohm)

 

Please find the pin-assignment 

on the next page! 

5 = 5 V   output;  330 kHz filter

 

10 = 10 V output;  330 kHz filter

Terminate RS-485

Connect GND to GND

P

C12 V to +V (pin 6)
Terminate RS-485

Connect chassis to GND
Connect chassis to GND
Connect chassis to GND

Activate ORION RS-485 (A)
Activate ORION RS-485 (B)

Activate analog output 0 on CH 14

Activate analog output 1 on CH 15

Note: If you connect signals to these 

contacts you have to open the solder 

jumpers W10 and W11 first! 

Connection to CH14 (pin 7)

Connection to CH15 (pin 7)

Содержание DEWE-50-USB2-16-NI

Страница 1: ...O9001 D E W E 5 0 U S B 2 1 6 N I www dewetron com T e c h n i c a l r e f e r e n c e m a n u a l A u t o m o t i v e E n e r g y P o w e r A n a l y s i s F i e l d S e r v i c e E n v i r o n m e n...

Страница 2: ...ation which is protected by copyright All rights are reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws All trade...

Страница 3: ...ral Information Safety Instructions 5 Warranty Information 5 Support 5 Printing History 5 Safety symbols in the manual 6 Safety instructions for all DEWETRON systems 7 Environmental Considerations 8 M...

Страница 4: ...4 Technical Reference...

Страница 5: ...TRON directly For Asia and Europe please contact For the Americas please contact DEWETRON Ges m b H Parkring 4 A 8074 Graz Grambach AUSTRIA Tel 43 316 3070 Fax 43 316 307090 Email support dewetron com...

Страница 6: ...service and repair of this product Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design manufacture and intended use of the...

Страница 7: ...removal unless you are qualified to do so No modifications are allowed at the instrument The fuse in the power module has to be replaced by the same type For continued protection against fire replace...

Страница 8: ...nvironmental impact of the product Product End of Life Handling Observe the following guidelines when recycling a DEWETRON system System and Components Recycling Production of these components require...

Страница 9: ...V 10 V USB interface on board Operating temperature 0 C to 50 C standard Storage temperature 20 C to 60 C Humidity operating 10 to 80 non condensing 5 to 95 rel humidity Vibration MIL STD 810F 514 5...

Страница 10: ...10 Main System...

Страница 11: ...Conversion Detailed information about the A D card are not included in this manual For detailed information see the manufacturer s A D card manual D A Conversion Detailed information about the D A ca...

Страница 12: ...A2 A D D A Conversion Notes...

Страница 13: ...oard 8 V sensor supply 9 9 V power supply The 16 slot DEWE MOTHERBOARD receives the 12 VDC power supply via a DC DC converter from the internal power supply 5 V ORION Ext CLK Ext TRIG DGND ORION Ext C...

Страница 14: ...3 W4 W5 W6 W7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65...

Страница 15: ...ctives 73 23 EEC Directive on the approximation of the laws of the Member States relating to electrical equipment designed for use within certain voltage limits amended by the directive 93 68 EEC 89 3...

Страница 16: ...C2 Notes...