background image

VIBRO KIT

TECHNICAL REFERENCE MANUAL

Do not switch on the system after transporting it from a cold into a warm room and vice versa.
The thereby created condensation may damage your system. Acclimatize the system unpowered
to room temperature.

Do not disassemble the system! There is a high risk of getting a perilous electric shock.
Capacitors still might be charged, even if the system has been removed from the power supply.

The electrical installations and equipment in industrial facilities must be observed by the security
regulations and insurance institutions.

The use of the measuring system in schools and other training facilities must be observed by
skilled personnel.

The measuring systems are not designed for use in humans and animals.

Please contact a professional if you have doubts about the method of operation, safety or the
connection of the system.

Please be careful with the product. Shocks, hits and dropping it from already-  lower level may
damage your system.

Please also consider the detailed technical reference manual as well as the security advice of the
connected systems.

This product has left the factory in safety-related flawlessness and in proper condition. In order to
maintain this condition and guarantee safety use, the user has to consider the security advice
and warnings in this manual.

EN 61326-3-1:2008

IEC 61326-1 applies to this part of IEC 61326 but is limited to systems and equipment for industrial
applications intended to perform safety functions as defined in IEC 61508 with SIL 1-3.

The electromagnetic environments encompassed by this product family standard are industrial, both
indoor and outdoor, as described for industrial locations in IEC 61000-6-2 or defined in 3.7 of IEC 61326-1.

Equipment and systems intended for use in other electromagnetic environments, for example, in the
process industry or in environments with potentially explosive atmospheres, are excluded from the
scope of this product family standard, IEC 61326-3-1.

Devices and systems according to IEC 61508 or IEC 61511 which are considered as “operationally
well-tried”, are excluded from the scope of IEC 61326-3-1.

Fire-alarm and safety-alarm systems, intended for the protection of buildings, are excluded from the
scope of IEC 61326-3-1.

9 Documentation version history

Revision

Author

Date

Comment

1.0

Jernej Sirk

25/04/2018

Initial version

V20-1

PL

03/09/2020

New template, added scope of supply, changed

structure of chapters, added Vibro-kit parts description

chapter

VIBRO KIT V20-1

29/29

Содержание VIBRO KIT V20-2

Страница 1: ...VIBRO KIT TECHNICAL REFERENCE MANUAL VIBRO KIT V20 2...

Страница 2: ...8 4 5 Torsional vibration 20 5 Specifications HW v1 3 22 6 User interface FW v1 9 22 6 1 Manual mode 22 6 2 Ramp mode 23 6 3 Analog in mode 24 6 4 PWM in mode 24 7 Warranty information 25 7 1 Calibrat...

Страница 3: ...VIBRO KIT TECHNICAL REFERENCE MANUAL 9 Documentation version history 29 VIBRO KIT V20 1 3 29...

Страница 4: ...bols and formats will be used throughout the document Important It gives you important information about the subject Please read carefully Hint It gives you a hint or provides additional information a...

Страница 5: ...ontrolled manually by a turn knob or you can completely define ramps cycles etc with the built in display Furthermore an external analog voltage or even PWM signal can be used to control the RPM Funct...

Страница 6: ...he left side refers to the Tacho 1 output signal and right side refers to the Tacho 2 output signal Image 1 Vibro kit unit Counter input connectors on cable Pin Name Description 1 IN0 A Output A 2 IN1...

Страница 7: ...sensor on the bottom side of the chassis for measuring signal of the striped tape on the rotating disc which is affixed on the shaft of the motor Please see chapter 3 3 1 Encoders to define which sens...

Страница 8: ...el Button on the top serves as a ON OFF start button for the motor The front knob serves as a navigation knob for the Menu Display shows general values and motor options when Vibro kit is turned on Im...

Страница 9: ...VIBRO KIT TECHNICAL REFERENCE MANUAL 3 3 4 Back panel Image 4 Back panel of drive part Power supply connector Pin Name Description 1 V Power supply 12V 36V 2 V Ground VIBRO KIT V20 1 9 29...

Страница 10: ...the RPM of an internal motor with voltage signal Tacho 1 Out BNC female connector Measuring an output signal from an optical sensor that is integrated below the rotating disk Tacho 2 Out BNC female c...

Страница 11: ...illation until the moving parts are equalized Black round plate has a white dotted strap on it which you can read with the tacho sensor Image 5 Flexible coupling on the right side The left encoder is...

Страница 12: ...t time of the rising edge of the signal with an additional counter Image 7 Super counter Frequency super counter mode has many advantages over traditional counter measurements The problem with traditi...

Страница 13: ...the setup of the channel where your encoder is connected Change the Basic application to the Sensor and choose the correct sensor from the dropdown list If your sensor is not on the list you can add i...

Страница 14: ...le and Raw count on the same recorder When the Vibro Kit is running press Freeze and zoom into the signal You can see how DewesoftX interpolates the angle values and is not updated only when a new pul...

Страница 15: ...ter Glue the accelerometer on the Vibro Kit Connect the accelerometer to the SIRIUS ACC module and enter the channel setup Select the IEPE mode if the sensor has a TEDS chip the sensitivity will be re...

Страница 16: ...T TECHNICAL REFERENCE MANUAL Image 12 FFT analyser settings Enter the measure mode and add the FFT channel on a 2D graph Run the machine and observe the FFT Image 13 FFT math on 2D graph VIBRO KIT V20...

Страница 17: ...rometer Glue the accelerometer on the Vibro Kit and connect it to the ACC module Connect encoder to the CNT module Open channel setup and set the acceleration sensor to IEPE mode and enter the correct...

Страница 18: ...Image 15 Order tracking screen 4 4 Balancing Additional needed equipment SIRIUS with one ACC single plane balancing or two ACC modules dual plane balancing accelerometer single plane balancing or two...

Страница 19: ...ght perform a trial run to get another unbalance vector From those two unbalanced vectors we calculate the correction mass that has to be added and the angle at which this should be added You can perf...

Страница 20: ...put channel from the module Detailed description of the parameters and setting can be found here https training dewesoft com online course rotational and torsional vibration Image 18 Torsional vibrati...

Страница 21: ...VIBRO KIT TECHNICAL REFERENCE MANUAL Image 19 Torsional vibration screen VIBRO KIT V20 1 21 29...

Страница 22: ...024 P R Right Encoder 360 P R 6 User interface FW v1 9 After power up the Main Menu is shown Select one of the following modes 1 MANUAL 2 RAMP 3 ANALOG 4 PWM IN 6 1 Manual mode Set output voltage to s...

Страница 23: ..._SW for 1sec Enabling the motor after the motor voltage has been set too high may result in input current limiter tripping resulting in system power down Disconnect and reconnect power supply to resta...

Страница 24: ...uickly leading to input current limiter tripping Enable motor by holding RUN_SW for 1sec ON is displayed Input voltage is scaled 1 1 to motor output voltage Regardless of input voltage motor voltage i...

Страница 25: ...alibrated at regular intervals The standard norm across nearly every industry is annual calibration Before your Dewesoft data acquisition system is delivered it is calibrated Detailed calibration repo...

Страница 26: ...he logo When used in text representing the company product or technology name the sign is not used The Dewesoft triangle logo is a registered trademark but the sign is not used in the visual represent...

Страница 27: ...Use this system under the terms of the specifications only to avoid any possible danger Read your manual before operating the system Observe local laws when using the instrument DO NOT touch internal...

Страница 28: ...aged obviously or causes strange noises The system does not work anymore The system has been exposed to long storage in adverse environments The system has been exposed to heavy shipment strain Warran...

Страница 29: ...ssness and in proper condition In order to maintain this condition and guarantee safety use the user has to consider the security advice and warnings in this manual EN 61326 3 1 2008 IEC 61326 1 appli...

Отзывы: