Dewert User Manual Model 2410XL - Updated 05.2021/1 MDR                                                                Page 4 of 12 

1.8 Model designation and type labelling 

The exact model designation depends on the choice of frame colour:  

-00 white powder coated (RAL 9010); 
-03 white aluminium powder coated (RAL 9006); 
-04 grey aluminium powder coated (RAL 9007) 

      
The type plate is attached to the underframe on one long side of the table. It provides information about key 
table data. 
The following symbols are listed there (by way of example), their meanings are: 
 

 
Read the operating 
manual   

 
     Serial no. 

 
Applied part Type B  

                   
Caution, potential 
hazard 

 
Max. load 
capacity 

 
    CE mark 
 

 
Date of manufacture 

      
     Product may only  
     be used in dry  

                        rooms 

 
  Do not dispose of with  
  household waste 

 
Address of 
manufacturer 

         Protective  
         insulation,  
         protection class II 

 

 
 

1.9 Meaning of the serial number 

The serial no. is located on the type plate or shown separately next to the type plate of the table. This number 
is unique and firmly linked to this specific individual product. It enables us to identify this table model and 
trace back assemblies/safety-relevant components at any time.  
Please always state this serial number when enquiring about spare parts.  
 
 

2. Operating manual 

 
2.1 Table design 

When designing the table frames, special emphasis was placed on functional and operational safety. The 
number of possible pinching points has thus been minimised, while remaining ones have been covered or 
protected with spacers to prevent injury, thus ensuring safe and yet simple operation. Nevertheless, 
necessary caution must always be exercised when using the table. 
 

 

The table consists of the following assemblies: - underframe, - scissor section, - upper frame, - upholstery.  
Depending on the respective version, these assemblies can feature further attachment parts. The surfaces of 
the welded design are plastic coated. The hydraulic system for height adjustment is located between the 
scissor section and the underframe, which guarantees very high power transmission even in the lowest 
adjustment range (min. height). Operating the lateral pedal causes the lifting tube of the hydraulic system to 
extend or retract. The scissors are thus pushed apart or together, thus enabling adjustment of the lying 
surface.  
 

 
2.2 Height adjustment 
 
Height adjustment 

The height is adjusted by repeatedly depressing (pumping) the foot lever on one side of the table. To lower 
the table, the foot lever is simply lifted with your foot.  
If the table is only lifted slightly each time the foot lever is depressed after transport or a longer period of non-
use, air bubbles have formed in the hydraulic system. To remove the air bubbles, pump the table upwards 
under load and perform an additional 20 - 30 strokes of the pump when the table is in the uppermost position. 
This will force air out of the system. 

Содержание 2410XL/H

Страница 1: ...Safety regulations 2 1 4 Intended purpose 2 1 5 Information on setup and use 3 1 6 Commissioning 3 1 7 Safety instructions 3 1 8 Model designation and type labelling 4 1 9 Meaning of the serial number...

Страница 2: ...g manual fully The manufacturer cannot be held responsible for damage caused by or involving unauthorised persons The user must ensure that the device is not accessible to unauthorised persons or cann...

Страница 3: ...strictly prohibited and possibly dangerous The manufacturer cannot be held responsible for damage caused by improper use Patients may only be positioned in preparation for treatment examination by pr...

Страница 4: ...al safety The number of possible pinching points has thus been minimised while remaining ones have been covered or protected with spacers to prevent injury thus ensuring safe and yet simple operation...

Страница 5: ...with infusions 2 4 Movability The table is equipped with easy running comfort castors measuring 150 mm in diameter in a conductive design Central movability By operating a lever on the outside of the...

Страница 6: ...ts of a holding bar and retaining pins that are attached below the bumpers on the head part In addition to the stainless steel bar the paper roll holding bar consists of a spring loaded stainless stee...

Страница 7: ...vents dust from entering through the dust lip and preserves the service life of the unit Caution When cleaning secure the table against unintentional lowering of the lying surface To do so set all the...

Страница 8: ...liable for damages resulting from uncoordinated modifications Only original Dewert spare parts may be used Gas springs are wearing parts whose function may be impaired over the years depending on the...

Страница 9: ...sposal costs meaning you can dispose of the packaging free of charge Product Safety notices o Pay attention to sharp edges and pointed objects o When transporting the table only take hold of the under...

Страница 10: ...similar medical devices have knowledge of its proper use taking into account possible hazards Ideal positioning of patients for the purpose of transport to pre treatment or post treatment locations a...

Страница 11: ...damaged All switches and supply lines undamaged Function check With electromotive adjustment Move all motors with the foot switch or the hand switch to both limit positions until automatic switch off...

Страница 12: ...ssories Accessories such as belts belt pads belt guides paper roll holders armrests etc undamaged and is proper and secure fixing function possible All necessary toggle screws present Possible movabil...