background image

Dewert User Manual 2000XL Series– Updated 05.2021/1 MDR                                                                Page 1 of 19 

User Manual  

 

2000XL series model   

 
Dear customer, 
 

Congratulations on purchasing a product of outstanding quality. 
Use of the best materials from renowned suppliers guarantees years of trouble-free operation, provided the 
device is handled correctly and as intended in accordance with the conditions described in the user manual. 
In the unlikely event you need to make a claim, please contact us. 
We welcome suggestions from the users of our products. 
 

Contents 

1. 

Safety information .................................................................................................................................... 2 

1.1 

Applied symbols .............................................................................................................................. 2 

1.2 

Applied standards ............................................................................................................................ 2 

1.3 

Safety regulations ............................................................................................................................ 2 

1.4 

Intended purpose ............................................................................................................................. 2 

1.5 

Information on setup and use .......................................................................................................... 3 

1.6 

Commissioning ................................................................................................................................ 3 

1.7 

Safety notices  ................................................................................................................................. 3 

1.8 

Model designation and type labelling .............................................................................................. 4 

1.9      Meaning of the serial number .......................................................................................................... 4 

2. 

Operating manual .................................................................................................................................... 5 

2.1 

Table design .................................................................................................................................... 5 

2.2 

Height adjustment ............................................................................................................................ 5 

2.3 

Head part adjustment ...................................................................................................................... 5 

2.4 

Adjustment of other sections ........................................................................................................... 6 

2.5 

Movability (model dependent or optional) ....................................................................................... 6 

2.6 

Additional equipment ....................................................................................................................... 7 

2.7 

Echocardiography tables ................................................................................................................. 8 

3.  Additional accessories (for user-specific table configuration), in extracts ................................................. 9 
4. Technical data ........................................................................................................................................... 10 

4.1 

Individual models of the 2000XL series ......................................................................................... 10 

4.2 

Technical data for electric motor ................................................................................................... 13 

4.3 

Technical data for hydraulic system .............................................................................................. 13 

5. 

Cleaning instructions ............................................................................................................................. 13 

6. 

Maintenance and technical inspection .................................................................................................. 14 

7. 

Safety devices ....................................................................................................................................... 15 

8.    Reporting obligation ............................................................................................................................... 16 
9.    Disposal ................................................................................................................................................. 16 
10.  Declaration of Conformity ...................................................................................................................... 17 

 

 
 

 

K.H. DEWERT GmbH 
Vollmestr. 7 
33649 Bielefeld 
Germany 
Tel. +49 / 521 400 27-0 
Fax +49 / 521 400 27-27 
[email protected] 
www.khdewert.de 

 

Содержание 2000XL Series

Страница 1: ...se 3 1 6 Commissioning 3 1 7 Safety notices 3 1 8 Model designation and type labelling 4 1 9 Meaning of the serial number 4 2 Operating manual 5 2 1 Table design 5 2 2 Height adjustment 5 2 3 Head par...

Страница 2: ...st important safety information Correct operation of the device is essential for safe operation Therefore please familiarise yourself with the contents of these instructions for use before using the d...

Страница 3: ...Hold and lift the table on the left and right hand side of the underframe The table must stand securely on its feet or castors on a level flat and solid surface Before use activate the brakes on the c...

Страница 4: ...express permission of the manufacturer When transporting the table take hold of the underframe NOT the upper frame 1 8 Model designation and type labelling The exact model designation depends on the c...

Страница 5: ...ke place beforehand see section 7 Alternatively the switch rails can also be led out to the short side of the table This facilitates height adjustment from the short sides of the table The lifting mot...

Страница 6: ...end position head down feet up inclined position To lower press down the lying surface and operate the release lever at the same time Once the desired position has been reached let go of the release l...

Страница 7: ...ose opening reach under the head part when the table is standing still and press the cushion out from the bottom upwards a slight amount of pressure is required To close it simply insert the cushion i...

Страница 8: ...d by tightening the screws The moving parts of the side guard should be re lubricated slightly at regular intervals spray oil e g Ballistol Side guard lowerable for side rail This side guard can be pl...

Страница 9: ...sm Comfort twin castors 100 or 125 mm individually lockable Paper roll holder for examination tables Paper roll holder for transport recovery tables Side rails Fastening clamp for side rail Infusion p...

Страница 10: ...on equipment kg 75 80 75 80 75 80 75 80 Min max height mm 500 940 520 940 500 940 520 940 Adjustment time motor s 22 22 Head part adjustment range ratchets 0 30 0 30 Head part adjustment range gas sp...

Страница 11: ...00 650 800 Head part length mm 750 750 570 750 Weight approx depending on equipment kg 105 105 125 135 125 135 Min max height mm 630 1050 630 1050 570 990 570 990 Head part adjustment range gas spring...

Страница 12: ...35XLE 2035XL H Max length mm 1950 1950 Width mm 700 800 700 800 Head part length mm 750 750 Weight approx depending on equipment kg 75 80 75 80 Min max height mm 480 920 500 920 Adjustment time motor...

Страница 13: ...es within the meaning of EN 50082 Part 1 and 2 Model 2052XLE 2053XLE is equipped with a second electric motor Both motors are connected to the mains by a power cable 4 3 Technical data for hydraulic s...

Страница 14: ...manufactured in such a way that it will operate safely over a very long period of time if used as intended and in a correct manner Depending on the conditions of use place of use and care the expected...

Страница 15: ...they cannot be triggered accidentally by patients users or third parties The actuator of this table is equipped with an integrated safety device to protect against unauthorised unintentional operation...

Страница 16: ...Packaging Safety notice Pay attention to sharp edges and pointed objects during disposal The packaging materials produced are mainly o Cardboard Paper o Plastic o Wood when delivered on a pallet Pleas...

Страница 17: ...th therapy Table operation and patient positioning on the table may only be performed by professionally trained persons who have been instructed in its use or who through experience with other similar...

Страница 18: ...damaged All switches and supply lines undamaged Function check With electromotive adjustment Move all motors with the foot switch or the hand switch to both limit positions until automatic switch off...

Страница 19: ...ssories Accessories such as belts belt pads belt guides paper roll holders armrests etc undamaged and is proper and secure fixing function possible All necessary toggle screws present Possible movabil...