19. Malfunction code
Field Service Ver. 1.0 Aug. 2005
238
bizhub 200/250/350
T
roubleshooting
*1: Not supported by this machine
19.2 How to reset
• Different malfunction resetting procedures apply depending on the rank of the trouble
code.
* List of Malfunction Resetting Procedures
C5351
Power Supply Cooling Fan
Motor Failure
• The Power Supply Cooling Fan Motor Lock sig-
nal remains set to H for a set period of time while
the Power Supply Cooling Fan Motor is turning.
• The Power Supply Cooling Fan Motor Lock sig-
nal remains set to L for a set period of time while
the Power Supply Cooling Fan Motor remains
stopped.
B
C5352
Cooling Fan Motor Failure
• The Cooling Fan Motor Lock signal remains set
to H for a set period of time while the Cooling
Fan Motor is turning.
• The Cooling Fan Motor Lock signal remains set
to L for a set period of time while the Cooling Fan
Motor remains stopped.
B
C5353
IU Cooling Fan Motor Failure
• The IU Cooling Fan Motor Lock signal remains
set to H for a set period of time while the IU Cool-
ing Fan Motor is turning.
• The IU Cooling Fan Motor Lock signal remains
set to L for a set period of time while the IU Cool-
ing Fan Motor remains stopped.
B
C8301
EDH Fan Motor Failure
☞
See DF-605 Service Manual.
C
CA052
MIO Device Failure
• The MIO device does not operate properly.
C
CC153
Flash ROM Failure
• The Flash ROM data was determined to be faulty
when the unit was turned on.
B
CC155
Exit Option Flash ROM Failure
☞
See FS-508 Service Manual.
B
Code
Item
Description
Rank
Trouble Code Rank
Resetting Procedures
Rank A
• Trouble Reset
☞
For details, see Adjustment/Setting.
Rank B
• Opening/Closing the front door
Rank C
• Turn OFF the Main Power Switch, wait for 10 sec. or
more, and turn ON the Main Power Switch.
Содержание ineo 250
Страница 1: ...ineo 250 350 Dynamic balance www develop de Service Manual Field ...
Страница 21: ...SAFETY AND IMPORTANT WARNING ITEMS S 18 4040P0C501DA High voltage ...
Страница 26: ...ineo 250 350 Main Unit Dynamic balance www develop de Service Manual Field ...
Страница 45: ...3 Built in Controllers Field Service Ver 1 0 Aug 2005 6 bizhub 200 250 350 General Blank Page ...
Страница 184: ...Field Service Ver 1 0 Aug 2005 9 Utility Counter Mode 145 bizhub 200 250 350 Adjustment Setting Blank Page ...
Страница 206: ...Field Service Ver 1 0 Aug 2005 11 Tech Rep Mode 167 bizhub 200 250 350 Adjustment Setting 4040F3E549DA ...
Страница 331: ...25 Timing chart Field Service Ver 1 0 Aug 2005 292 bizhub 200 250 350 Appendix 4040F5E522DA ...
Страница 334: ...Duplex Unit Switchback Unit Dynamic balance www develop de Service Manual Field ...
Страница 339: ...1 Product specifications Field Service Ver 1 0 Aug 2005 2 Duplex Unit Switchback Unit General Blank Page ...
Страница 352: ...ineo 250 350 Standard Controller Dynamic balance www develop de Service Manual Field ...
Страница 355: ...Standard Controller General Maintenance Troubleshooting Field Service Ver 1 0 Aug 2005 ii Blank Page ...
Страница 363: ...3 Troubleshooting procedures Field Service Ver 1 0 Aug 2005 8 Standard Controller Troubleshooting Blank Page ...
Страница 364: ...FK 503 Dynamic balance www develop de Service Manual Field ...
Страница 369: ...FK 503 General Maintenance Adjustment Setting Troubleshooting Field Service Ver 1 0 Aug 2005 iv Blank Page ...
Страница 373: ...1 Product specifications Field Service Ver 1 0 Aug 2005 4 FK 503 General Blank Page ...
Страница 379: ...4 Disassembly Reassembly Field Service Ver 1 0 Aug 2005 10 FK 503 Maintenance Blank Page ...
Страница 529: ...11 Soft Switch List Field Service Ver 1 0 Aug 2005 160 FK 503 Adjustment Setting Blank Page ...
Страница 542: ...DF 605 Dynamic balance www develop de Service Manual Field ...
Страница 549: ...1 Product specifications Field Service Ver 1 0 Aug 2005 4 DF 605 General Blank Page ...
Страница 578: ...PC 102 PC 202 Dynamic balance www develop de Service Manual Field ...
Страница 583: ...1 Product specifications Field Service Ver 1 0 Aug 2005 2 PC 102 PC 202 General Blank Page ...
Страница 601: ...6 Mechanical adjustment Field Service Ver 1 0 Aug 2005 20 PC 102 PC 202 Adjustment Setting Blank Page ...
Страница 609: ...8 Trouble code Field Service Ver 1 0 Aug 2005 28 PC 102 PC 202 Troubleshooting Blank Page ...
Страница 610: ...PC 402 Dynamic balance www develop de Service Manual Field ...
Страница 615: ...1 Product specification Field Service Ver 1 0 Aug 2005 2 PC 402 General Blank Page ...
Страница 629: ...3 Other Field Service Ver 1 0 Aug 2005 16 PC 402 Maintenance Blank Page ...
Страница 649: ...8 Trouble code Field Service Ver 1 0 Aug 2005 36 PC 402 Troubleshooting Blank Page ...
Страница 650: ...JS 502 Dynamic balance www develop de Service Manual Field ...
Страница 653: ...JS 502 General Maintenance Adjustment Setting Field Service Ver 1 0 Aug 2005 ii Blank Page ...
Страница 655: ...1 System configuration Field Service Ver 1 0 Aug 2005 2 JS 502 General Blank Page ...
Страница 660: ...FS 508 PU 501 OT 601 Dynamic balance www develop de Service Manual Field ...
Страница 687: ...4 Other Field Service Ver 1 0 Aug 2005 22 FS 508 PU 501 OT 601 Maintenance Blank Page ...
Страница 699: ...8 Mechanical adjustment Field Service Ver 1 0 Aug 2005 34 FS 508 PU 501 OT 601 Adjustment Setting Blank Page ...
Страница 713: ...10 Malfunction code Field Service Ver 1 0 Aug 2005 48 FS 508 PU 501 OT 601 Troubleshooting Blank Page ...
Страница 714: ...MT 501 Dynamic balance www develop de Service Manual Field ...
Страница 717: ...MT 501 General Maintenance Adjustment Setting Troubleshooting Field Service Ver 1 0 Aug 2005 ii Blank Page ...
Страница 719: ...1 Product specification Field Service Ver 1 0 Aug 2005 2 MT 501 General Blank Page ...
Страница 732: ...SD 502 Dynamic balance www develop de Service Manual Field ...
Страница 737: ...1 Product specifications Field Service Ver 1 0 Aug 2005 2 SD 502 General Blank Page ...