FrameMaker Ver5.5E(PC) Di152/Di183 MECHANICAL/ELECTRICAL
01.09.05
M-24
12-5.
Toner Replenishing Mechanism
• Toner is supplied from the Toner Bottle to the Developer Mixing Chamber.
1. The coupling is turned by the motor, which turns the Toner Bottle.
2. To regulate the amount of toner supplied from the Toner Bottle, there is a Metering
Chamber provided in the outer race of the coupling.
3. When the Toner Bottle turns, toner in the Metering Chamber drops.
4. Toner from the metering chamber is conveyed by the Toner Conveying Screw into the
Developer Mixing Chamber.
5. The Toner Conveying Screw is turned by the motor.
Elevtrical Component
Control Signal
ON
OFF
Wiring Diagram
M6
PWB-A PJ19A-6
L
H
4-B
4021M020AB
4021M021AB
4021M022AA
4021M023AA
Toner Bottle
coupling
Developer Mixing Chamber
Toner Conveying Screw
Metering
Chamber
Содержание D1531iD
Страница 2: ...FrameMaker Ver5 5E PC Di152 Di183 GENERAL 01 08 27 GENERAL 14413 ...
Страница 3: ......
Страница 5: ......
Страница 15: ......
Страница 16: ...FrameMaker Ver5 5E PC Di152 Di183 MECHANICAL ELECTRICAL 01 09 05 MECHANICAL ELECTRICAL 14413 ...
Страница 17: ......
Страница 73: ......
Страница 84: ...FrameMaker Ver5 5E PC Di152 Di183 DIS REASSEMBLY ADJUSTMENT 01 09 03 DIS REASSEMBLY ADJUSTMENT 10230 ...
Страница 85: ......
Страница 89: ......
Страница 160: ...FrameMaker Ver5 5E PC Di152 Di183 SWITCHES ON PWBs TECH REP SETTINGS 01 07 26 SWITCHES ON PWBs TECH REP SETTINGS 17196 ...
Страница 161: ......
Страница 163: ......
Страница 193: ......
Страница 194: ...FrameMaker Ver 5 5E PC Di152 Di183 TROUBLESHOOTING 01 09 04 TROUBLESHOOTING 14390 ...
Страница 195: ......
Страница 259: ......