Scanner Motor Drive Control
• The speed at which the Scanner is moved is controlled by varying the period of the motor
drive pulse that is timed with the reference clock.
• The distance over which the Scanner travels is controlled by the number of motor drive
pulses that correspond to each paper size and zoom ratio.
Elevtrical Component
Control Signal
ON
OFF
Wiring Diagram
M5
PWB-C JP5C-1 to 4
Pulse output
11-B
High Speed
Low Speed
Period