FrameMaker Ver.5.5E(PC) Di152/Di183 TROUBLESHOOTING
01.09.04
T-40
(16) The copier does not turn ON.
Relevant Electrical Parts
Power Switch (S1)
DC Power Supply (PU1)
Control Panel (UN2)
Control Board (copier: PWB-C)
Master Board (copier: PWB-A)
Step
Check
Result
Action
1
A malfunction code appears when
the Power Switch is turned ON.
YES
• Go to step 2.
NO
• Go to step 3.
2
The malfunction is temporarily reset
when the Power Switch is turned
OFF and ON with the Stop key held
down.
YES
• Perform the troubleshooting proce-
dure according to the malfunction
code.
JP2UN2
JP4C
1
29
30
2
PJ11C
1
29
30
2
PJ1A
PWB-A
Master Boad
PWB-C
Control Boad
UN2
Control
Panel
Main Switch
Fusing Unit
Interlock Switch
Fusing
Heater Lamp Thermoswitch 1
Front Door
InterLock Switch
Right Door
InterLock Switch
PU1
DC Power Supply
4022T545AA
Содержание D1531iD
Страница 2: ...FrameMaker Ver5 5E PC Di152 Di183 GENERAL 01 08 27 GENERAL 14413 ...
Страница 3: ......
Страница 5: ......
Страница 15: ......
Страница 16: ...FrameMaker Ver5 5E PC Di152 Di183 MECHANICAL ELECTRICAL 01 09 05 MECHANICAL ELECTRICAL 14413 ...
Страница 17: ......
Страница 73: ......
Страница 84: ...FrameMaker Ver5 5E PC Di152 Di183 DIS REASSEMBLY ADJUSTMENT 01 09 03 DIS REASSEMBLY ADJUSTMENT 10230 ...
Страница 85: ......
Страница 89: ......
Страница 160: ...FrameMaker Ver5 5E PC Di152 Di183 SWITCHES ON PWBs TECH REP SETTINGS 01 07 26 SWITCHES ON PWBs TECH REP SETTINGS 17196 ...
Страница 161: ......
Страница 163: ......
Страница 193: ......
Страница 194: ...FrameMaker Ver 5 5E PC Di152 Di183 TROUBLESHOOTING 01 09 04 TROUBLESHOOTING 14390 ...
Страница 195: ......
Страница 259: ......