FrameMaker Ver.5.5E(PC) Di152/Di183 TROUBLESHOOTING
01.09.04
T-35
(11) C1038: Engine connection failure
(12) C1200: Faulty ASIC/memory
Relevant Electrical Parts
Master Board (copier: PWB-A)
Control Board (copier: PWB-C)
Step
Check
Result
Action
1
C1038 reappears when the copier is
turned OFF and ON again.
<Check Procedure>
Turn OFF and ON the Power Switch
to check to see if C1038 reappears.
YES
• Go to step 2.
2
The connection between Master
Board (copier: PWB-A) and Control
Board (copier: PWB-C) is loose.
YES
• Make good connection between
Master Board (copier: PWB-A) and
Control Board (copier: PWB-C).
NO
• Change Control Board (copier:
PWB-C).
• Change Master Board (copier:
PWB-A).
Relevant Electrical Parts
Control Board (copier: PWB-C)
Step
Check
Result
Action
1
C1200 reappears when the copier is
turned OFF and ON again.
<Check Procedure>
Turn OFF and ON the Power Switch
to check to see if C1200 reappears.
YES
• Go to step 2.
2
Memory (U8) on Control Board
(copier: PWB-C) is loose.
YES
• Reinstall memory (U8).
NO
• Change Control Board (copier:
PWB-C).
Содержание D1531iD
Страница 2: ...FrameMaker Ver5 5E PC Di152 Di183 GENERAL 01 08 27 GENERAL 14413 ...
Страница 3: ......
Страница 5: ......
Страница 15: ......
Страница 16: ...FrameMaker Ver5 5E PC Di152 Di183 MECHANICAL ELECTRICAL 01 09 05 MECHANICAL ELECTRICAL 14413 ...
Страница 17: ......
Страница 73: ......
Страница 84: ...FrameMaker Ver5 5E PC Di152 Di183 DIS REASSEMBLY ADJUSTMENT 01 09 03 DIS REASSEMBLY ADJUSTMENT 10230 ...
Страница 85: ......
Страница 89: ......
Страница 160: ...FrameMaker Ver5 5E PC Di152 Di183 SWITCHES ON PWBs TECH REP SETTINGS 01 07 26 SWITCHES ON PWBs TECH REP SETTINGS 17196 ...
Страница 161: ......
Страница 163: ......
Страница 193: ......
Страница 194: ...FrameMaker Ver 5 5E PC Di152 Di183 TROUBLESHOOTING 01 09 04 TROUBLESHOOTING 14390 ...
Страница 195: ......
Страница 259: ......