LOGGER CHANNEL SETTINGS
Every Channel consists of a group of settings (explained in details below), which are used when
monitoring and alerting. Each preset has its own page where it is being configured. Measurement
windows can be set for each of the alarms, including trigger and alarm release times.
Channel
•
Name – channel alias;
•
Enable/Disable – enables/disables channel monitoring;
•
Frequency – specify the frequency to be monitored;
•
Acquisition time – specify the observation time for the current station (before switching to
the next channel);
• E-mail for alarm notofication to be sent.
NOTE:
When MPX Power alarm is enabled the observation time must be more than 60 seconds.
Alarm Notification Type
• E-mail – enables/disables E-mail notification;
• SMS – enables/disables SMS notification;
• SNMP – enables/disables SNMP notification;
•
GPO – enable/disable GPO action.
Logger mode alarms allow individual alarms for a frequency to be set. The Logger mode is
running only when there is no user interference. As up to 50 channels can be set, when in Logger
mode the DB4005 will monitor the status of each channel on a rotation principle, and as per the
user defined observation time. The alarm notification works as follows: if the observation time is
set to 10 seconds, and during this time the RF level (for example) is below the specified threshold,