Script and configuration
7
Script and configuration
7.1 Overview
The script stored in the UNIGATE
®
IC, as well as the configuration, can be replaced or updated
via the serial interface (application) in the configuration mode.
7.2 The configuration mode
If the pin „ConfigMode“ pulled to GND during the PowerUp or Reset, then the UNIGATE
®
IC
starts in the configuration mode. In this mode it is possible to communicate with the IC without
processing the regular software. In this mode it is possible to change the UNIGATE
®
IC’s settings
of the standard software or to write a new script in the UNIGATE
®
IC. It shows its start in the con-
figuration mode by issuing a status message, which might look as follows:
IC-EC-SC V0.3 [31] (c)dA Script(8k)="Leer" Author="Deutschmann Automation GmbH"
Version="1.0" Date=21.08.2001 SN=47110001
7.3 Update the script
•
The preferred option is to insert the UNIGATE
®
IC into the base board from Deutschmann
(Developer Board UNIGATE
®
IC-AB) and use the Deutschmann tools (software WINGATE with
„Write Script“ under „File“ or with the software ScriptProgramTool).
•
You can also automatically replace the script in your application from your host (see flowchart)