23.6.17
UNIGATE
®
fieldbus gateway UNIGATE
®
CM - CANopen V. 1.4
33
Deutschmann Automation GmbH & Co. KG
Error handling
11.1.1 Error on the extension
An error on the extension will be signaled through red flashing of the Power/State-LED. The LED
of the according error number turns off. This is followed by a short, then the flashing sequence is
repeated.
Example: With an SRAM-Error 3 the LED lights red, turns off 3 times, lights up again for a
moment and everything starts over. The following errors are possible on the extension.
Error Number
Error description
1
HARDWARE_ERROR
2
STACK_ERROR
FLASH_INIT_ERR
3
SRAM_ERROR
FLASH_ERROR
4
CL_KOMM_ERROR, e.g. CL Firmware doesn’t support an extension yet
5
BUS_ID_ERROR
FLASH_CHECK_ERR
6
CL_KOMM_RX_ERR
7
CL_KOMM_TX_ERR
8
NSW_DATA_ERROR
9
TIMOUT_ERROR
10
TX_ERROR
11
RX_ERROR
12
ID_ERROR, e.g. double Dicnet-ID, or ID not in net
24V_ERROR, overload (only at Option I/O8)
13
PARA_ERROR
14
BUS_ERROR
15
NSW_PROG_ERROR