INDUSTRIAL
3850 Industrial Avenue
•
Hemet, CA 92545
Title Drawing
Number
INSTRUCTION GUIDE FOR DTT-16-00
0425-037-0000
Revision Letter:
D
Engineering Order Number:
P20709
Page
1
of
2
I N F O R M A T I O N
Revisions
Sym Description
Date
Approved
B
Revised per E.O. P19503
1/08/08
R. Reed
C
Revised per E.O. P19727
2/21/08
D. Meyer
D
Revised per E.O. P20709
12/20/10
S. Beard
1. WIRE
PREPARATION
Prior to crimping contacts, wire must be stripped to a length of .175”
±
.025” [4.45
±
0.64]. Wire
should have no insulation tearing or stretching and no conductor strands missing or damaged.
2. CONTACT
LOADING
Cycle handles to release ratchet and fully open crimp jaws. Insert contact in cavity recommended for
wire size. Adjust alignment and width of crimp wings if necessary to insure capture by crimp jaws.
WARNING
:
Contacts may have sharp edges. Use finger protection to avoid cuts. Do not place fingers in
tool areas which may pinch during crimp cycle. Use safety glasses to avoid eye injury.
3. HAND-CRIMP
CYCLE
Close crimp tool until full-cycle ratchet control releases.
4. CONTACT
REMOVAL
After completing the crimp cycle, open jaws fully. Remove crimped contact.
5. MAINTENANCE
To ensure correct functioning, maintenance must be performed on a regular basis. This includes:
Lubrication of moving parts.
Removal of debris from jaw areas.
Visual inspection for loose hardware, broken or missing parts.
6.
RECOMMENDED CAVITY FOR WIRE GAUGE AND INSULATION TYPES
Use this chart to insure best crimp results with Deutsch stamped and formed contacts
106*-
14
-
01
**, 106*-
14
-
10
**, 106*-
16
-
01
**, 106*-
16
-
07
**, and 106*-
16
-
09
**:
NOTE: when
*
=
0
, P/N is
PIN
contact; when
*
=
2
, P/N is
SOCKET
contact
**
=
PLATING CODE
; see individual contact Envelope Drawings for available types.
Cavity METRIC
Wire Sizes
AWG
Insulation Types
A 1.0
mm²
A
16
T
XL,
16
G
XL, or
16
S
XL
B 1.5-2.0
mm²
B
14
T
XL,
14
G
XL or
14
G
XL