D. Meyer 

 
 

1. WIRE 

PREPARATION 

 

Prior to crimping contacts, wire must be stripped to a length of .250” 

±

 .025” [6.35

±

 0.64].   

Wire should have no insulation tearing or stretching and no conductor strands missing or damaged. 

 

2. CONTACT 

LOADING 

Cycle handles to release ratchet and fully open crimp jaws.  Insert contact into desired nest.  Verify 
that contact is fully inserted into locator block.  Adjust alignment and width of crimp wings if 
necessary to insure capture by crimp jaws. 

 

WARNING 

Terminals may have sharp edges.  Use finger protection to avoid cuts. 

Do not place fingers in tool areas, which may pinch during crimp cycle. 

Use safety glasses to avoid eye injury.

 

 

3. HAND-CRIMP 

CYCLE

 

 

Close crimp tool until full-cycle ratchet control releases. 

 

4. CONTACT 

REMOVAL

 

 

After completing the crimp cycle, open jaws fully. 

 

5. 

MAINTENANCE and INSPECTION

 

Maintenance and inspection should be performed regularly.  Tool should be wiped clean with special 
emphasis on the crimping cavities.  Tool may be cleaned by immersing in a suitable commercial 
solvent or cleaner which does not attack paints or plastic material.  The tool should be re-lubricated 
after cleaning using a light film of medium weight oil on bearing surfaces and pivot pins.  When not in 
use, keep handles closed to prevent objects from becoming lodged in the crimping dies.  Store in a 
clean dry area. 

 

6. 

RECOMMENDED CAVITY FOR WIRE GAUGE AND INSULATION TYPES 

 

 

Use this Table 1 to insure best crimp results with Deutsch stamped and formed contacts 

 

1060-12-01** (PIN), and 1062-12-01** (SOCKET): 

 

Table 1.

 Cavity and Wire Gage and Insulation Types 

Cavity 

Wire Gage and Insulation Types 

Insulation Range 

2.0 mm

2

14 AWG (SXL, GXL, TXL) 

2.5 mm

3.0 mm

12 AWG (TXL) 

.095 - .132 

[2.41 – 3.35] 

12 AWG (SXL, GXL) 

4.0 mm

.130 - .180 

[3.30 – 4.57] 

 
 
 

Отзывы: