1.
Inspect the cooling system hoses and replace any hose that shows obvious signs of damage or feels abnormally soft or
hard.
2.
Replace damaged clamps.
3.
Correct all external leaks as soon as detected.
NOTE:
If Detroit Genuine antifreeze/coolant (or equivalent fully formulated, pre-charged antifreeze is used, a pre-
charged element is not required.
4.
Check coolant inhibitor levels at the intervals listed in this manual.
Current engine designs no longer use coolant filters. If you have a coolant filter, you may choose to remove the filter
at your next maintenance interval. For more details reference bulletin
(
ddc.freightliner.com/cps/rde/xbcr/ddcsn/15TS10Rev.pdf
15.15 How to Service the Dry Type Air Cleaner
Maintain the air cleaner as follows:
1.
Replace dry type air cleaner elements when the maximum allowable air cleaner restriction has been reached. Air
cleaners are equipped with a restriction indicator which aids in determining the servicing interval.
2.
Do not clean and/or reuse a dry paper-type air cleaner.
EuroV MBE 900 Operators Manual
All information subject to change without notice.
61
DDC-SVC-MAN-0207
Copyright © 2019 DETROIT DIESEL CORPORATION