![Detroit Diesel DDEC VI Скачать руководство пользователя страница 333](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033333.webp)
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
5.21
PASSWORDS
DDEC VI is capable of providing password protection for groups of parameters or a
fl
eet
password for all parameters.
5.21.1
OPERATION
A Password of zero is used to deactivate the protection. The lockout passwords may be up to 4
ASCII characters. Each level can have its own unique password.
Passwords can be activated with DDDL 7.0, VEPS or DRS. Once activated the parameters may
not be changed until the correct password is reentered. The CPC is automatically locked at the
next ignition cycle.
Groups selected for additional password protection are listed in Table 5-69.
Level
Parameters Protected
1
General Password – all parameters in all groups will be protected when this level is set
2
Vehicle Speed Settings – parameter groups that contain primary settings governing the speed
of the vehicle. All parameters in following groups are protected when this password is set:
□
PGR003 – Common Limiters
□
PGR008 – Vehicle Speed Sensor
□
PGR015 – Cruise Control (minus the “Cruise Power” parameter for rating changes)
3
PTO / Idle Settings – parameter groups that contain settings related to idle, idle shutdown,
and PTO of the vehicle. All parameters in the following groups are protected when this
password is set:
□
PGR007 – PTO
□
PGR017 – Idle and PTO Shutdown
4
System Settings – parameter groups that contain settings related to systems on the vehicle.
All parameters in the following groups are protected when this password is set:
□
PGR002 – Vehicle Parameters I
□
PGR010 – Engine Brake
□
PGR012 – Optimized Idle
□
PGR019 – Automatic Fan Activation
5
Engine Protection Settings – the parameter group that contain settings for engine shutdown
options and Engine Rating Selection – There is one parameter in this section, the “Cruise
Power” parameter from group 15. This parameter allows the user to select from up to 3
different ratings within the same engine family (high power, low power, and cruise-power)
where applicable are protected when this password is set:
□
PGR018 – Engine Protection
□
Cruise Power (Parameter 15 in Cruise Control Group)
6
TBD
7
Export Settings
Table 5-69
Protected Parameters