10
Telephony Functions
Factory Settings on Delivery
Factory Settings on Delivery
The following basic settings and fea-
tures are active on delivery. We rec-
ommend that you configure the
OpenCom 100 to your individual re-
quirements before putting it into
operation (see
Telephony Functions
OpenCom 107/105
■
The S
0
1 port is configured for
multi-terminal access, the S
0
2
port for system access.
■
The S
0
3 and S
0
4 ports are con-
figured as internal S
0
buses with
the call numbers 20 and 21.
■
The four U
pn
ports are config-
ured for OpenPhone 63 system
telephones with the call num-
bers 30 to 33.
■
The four a/b ports are config-
ured for analogue devices with
the call numbers 10 to 13.
OpenCom 110
■
The S
0
1 port is configured for
multi-terminal access, the S
0
2
port for system access.
■
The S
0
3, S
0
4 and S
0
5 ports are
configured as internal S
0
buses
with the call numbers 20 to 22.
■
The eight U
pn
ports are config-
ured for OpenPhone 63 system
telephones with the call num-
bers 30 to 37.
■
The four a/b ports are config-
ured for analogue devices with
the call numbers 10 to 13.
OpenCom 120
■
The S
0
1 port is configured for
multi-terminal access, the S
0
2
port for system access.
■
The S
0
3 to S
0
6 ports are config-
ured as internal S
0
buses with
the call numbers 20 to 23.
■
The 18 U
pn
ports are configured
for OpenPhone 63 system tele-
phones with the call numbers 30
to 47.