3300-0329-0M Rev B 04/19
1
Digital Clinical Scale
with Remote Indicator
Owner’s Manual
Страница 1: ...3300 0329 0M Rev B 04 19 1 Digital Clinical Scale with Remote Indicator Owner s Manual...
Страница 2: ...the procedures do so entirely at their own risk FCC Compliance Statement This equipment generates uses can radiate radio frequency and if not installed and used in accordance with the instruction manu...
Страница 3: ...to reduce the effects of hazardous substances contained in electrical and electronic equipment on human health Please do your part by making certain that this device is properly disposed of The symbo...
Страница 4: ...y Page 13 Basic Operation Page 13 Body Mass Index BMI Operation Page 13 SCALE SETUP Page 15 DATA FORMATS Page 22 BLUETOOTH LOW ENERGY BLE Page 23 Enable BLE Page 23 Bluetooth Pairing Page 23 BLUETOOTH...
Страница 5: ...included or optional 100 to 240 VAC 50 60Hz 12 VDC 1 A wall plug in UL CSA listed AC power adapter Cardinal part number 6800 1047 Operating Environment Operated Temperature Range 14 to 104 F 10 to 40...
Страница 6: ...ghtning damage such as surge suppressors should be installed Electrical Power The Detecto apex Digital Clinical Scale with Remote Indicator has been designed to operate from a 100 to 240 VAC 50 60Hz 1...
Страница 7: ...ther components You should have the following components Scale Base with attached Display Scale Base Cover apex Wall Mount Kit includes mounting template 2 screws and 2 wall anchors ASSEMBLY 1 Place t...
Страница 8: ...gardless of how and where you mount the display it should be in a safe area where it will not be in the way of normal traffic The location chosen should be free of temperature extremes water and not i...
Страница 9: ...ent unit setting turned on If the setting displayed is acceptable press the key to save it Otherwise press the or keys to toggle the weighing units between lb pounds or kg kilograms and then press the...
Страница 10: ...isplay bracket stand and then plug the power adapter into the proper electrical outlet On models requiring 230 VAC it is the customer s responsibility to obtain the correct power adapter plug USB The...
Страница 11: ...tery status will be displayed when batteries are installed The battery bar graph on the display indicates the battery capacity in five steps 4 segments the full battery capacity is available 3 segment...
Страница 12: ...re No 10 6 If display turns on batteries have been installed correctly If not remove the platform cover and check for one or more improperly positioned batteries 7 The scale is now ready for operation...
Страница 13: ...orm the display will zero the weight up to 100 of the scale capacity When the weight is removed the display will show a negative weight value Press the 0 key again to reset the display to zero This is...
Страница 14: ...al completion of the data entry process the data entered and to send the weight and associated data to the USB port NOTE The scale will not respond to pressing the key unless the weight display is sta...
Страница 15: ...d during setup 0 ZERO This annunciator is turned on to indicate that the weight displayed is within 1 4 division of the center of zero LOCK This annunciator is turned on to show that the indicator is...
Страница 16: ...3300 0329 0M Rev B 04 19 12...
Страница 17: ...nto scale 4 When weight is stable the STABLE annunciator will turn 5 The weight reading will automatically lock and the annunciator resembling a padlock will turn on Note that the amount of time the r...
Страница 18: ...3300 0329 0M Rev B 04 19 14...
Страница 19: ...ng prompt will be shown in the smaller upper seven segment display while the value of the current setting will be shown in the large lower seven segment display Note that when moving through the setup...
Страница 20: ...nt setting If the value displayed is acceptable press the key Otherwise press the or keys to select a new value and then press the key to save it and proceed to the next prompt This is the number of t...
Страница 21: ...Otr and the current setting If the value displayed is acceptable press the key Otherwise press the or keys to select a new value and then press the key to save it and proceed to the next prompt This...
Страница 22: ...keys to toggle the USB Mode between PHdC Personal Healthcare Device Class Cont continuous output or POLL weight on demand and then press the key to save it and proceed to the next prompt This setting...
Страница 23: ...3 00 PM would be entered as 15 nnIn MINUTE The display will show nnIn and the current setting If the value displayed is acceptable press the key Otherwise press the or keys to select a new value and...
Страница 24: ...d the previous calibration will be retained To begin calibration press the key to select YES and then press the key After pressing the key the display will change to LOAd LOAd LOAD CALIBRATION WEIGHT...
Страница 25: ...to save it and proceed to the next prompt Allowable values for GrAu are 0 000 to 2 000 NOTE The default value is 1 000 which means there is no gravity compensation TYPE Scale Model The display will sh...
Страница 26: ...ENQ hex 05 An example and explanation of the data format transmitted is shown below SMA Format Cont or POll This format is used if the scale is configured for Cont continuous output OR if the scale i...
Страница 27: ...s the key until the prompt BLE for Bluetooth Low Energy Enable is displayed Use the or keys to change the selection to yes and press the key 4 Press the key to turn the scale off and then press it aga...
Страница 28: ...b30 d7aad5f83e54 All custom characteristics have the same base number of the Service UUID 0x907aXXXX 8699 47dd ab30 d7aad5f83e54 where the XXXX part distinguishes the service Characteristics Sub Numbe...
Страница 29: ...dely accepted BLE GATT profiles are used to transmit data to other devices software that have implemented these profiles Data is passed via BLE using GATT characteristic Weight Measurement 0x2A9D as d...
Страница 30: ...the proper selection 6 The next prompt will be IP1 If dHCP was set to On nothing needs to be entered here If dHCP was set to OFF enter the first octet of the static IP address For example if the stati...
Страница 31: ...uo xxxx where the xxxx varies Use a WiFi device such as a Smartphone or laptop to connect to the Duo module If the connection fails try moving the scale to another location or cycling power to the sca...
Страница 32: ...s To display the scale s IP address 1 With no weight on the scale press and hold the key 2 The display will change to all dashes followed by the software revision 3 Release the key The calibration cou...
Страница 33: ...OPERATION Web Server To see scale data with your WiFi device open a web browser and go to the IP address for the scale For example if the IP address is 192 168 0 102 enter http 192 168 0 102 and a pag...
Страница 34: ...ercapacity U below zero Space none of the preceding ASCII space 20 Hex wwwww weight UU Unit lb h feet height i i inches height bbb b BMI CR ASCII CR 0D Hex LF ASCII LF 0A Hex For metric units the form...
Страница 35: ...o Review the Event Counter 1 Press the key to turn the scale on 2 The scale will perform a display test turn on all segments and annunciators and then change to the show the software revision for a fe...
Страница 36: ...lay and BAtt on the large lower seven segment display Note that when the battery voltage drops too low for accurate weighing the scale will automatically shut off and you will be unable to turn it bac...
Страница 37: ...tools such as steel pads and scrapers which will scratch the painted surface Instead use soft cloths or plastic scouring pads for cleaning When possible use treated water Hard water can leave behind d...
Страница 38: ...ROMMET 1 4 ID X 5 8 OD FOR 1 8 TK 7 4 6540 1122 0 81DIA RUBBER FOOT 8 1 3300 0330 0A 72 APEX RI CABLE 9 8 6021 1550 FLAT HEAD CAP SCW M8X1 25X30MM 10 4 6021 0654 PAN HEAD SCW 06 32X 25 11 2 6021 1554...
Страница 39: ...8 DISPLAY ENCLOSURE 3 1 3300 0052 08 DISPLAY FRONT APEX 4 6 3300 0072 08 APEX BUTTONS 5 1 3300 0089 08 UNDERLAY FOAM APEX 6 1 3300 0334 08 3300 0335 08 3300 0336 08 3300 0337 08 UNDERLAY APEX RI UNDER...
Страница 40: ...freight both ways This warranty does not apply to peripheral equipment not manufactured by Detecto this equipment will be covered by certain manufacturer s warranty only This warranty does not include...
Страница 41: ...ranty or deficiency in connection with the sale or use of the product Detecto will not be liable for consequential damages of any nature including but not limited to loss of profit delays or expenses...
Страница 42: ...3300 0329 0M Rev B 04 19 38 3300 0329 0M Rev B 04 19 Printed in USA...