ASSEMBLING PUMP SET
DESMI Pumping Technology A/S
Tagholm 1
9400 Nørresundby
– Denmark
Tlf. nr.: +45 96 32 81 11
Fax +45 98 17 54 99
103
E-mail: [email protected] www.desmi.com
2. Fit cover under bearing (26). (Only for
Ø330/415/418/465/525)
For pumps with Lip seal in cover under bearing please read appendix A.
10.2.3. Fitting water deflector
Ø215/265
1. Assemble bearing cover and rear cover.
2. Lead the water deflector (11) over the shaft until
it touches the rear cover and then further 1-1.5
mm into the rear cover. Do not fasten bearing
cover and electric motor until the motor has
been mounted and the shaft can rotate freely
without noise.