background image

This Manual is applicable to the 

 

Revised January 2020 

De Sisti PICCOLETTO DIM 

 

Pag 4

.

 

4.

 

SAFETY INSTRUCTIONS 

 

Ü

 

Professional use: 

This luminaire has been designed for professional use and must be operated by qualified personnel 

only. 

Not for residential use. 

Ü

 

Grounding:   WARNING

: THIS LUMINAIRE MUST BE GROUNDED 

Ü

 

WARNING:

  Disconnect Power CORDS before  

 

any maintenance work or opening the FUSE HOLDER.  
Risk of serious injury. 

 

Ü

 

Electrical connections

IMPORTANT 

The cores in this mains lead are colored in accordance with the following code: 

 

Europe 

America 

Ground

 

Green & yellow

 

Green or green & yellow

 

Neutral

 

Blue

 

White

 

Live

 

Brown

 

Black

 

 

In case the colors of the cores do not correspond to the colors of the connection points on your plug, please proceed as 
follows: 

 

the green or green and yellow core must be connected to the connection point marked with the letter E or with the 
symbol  

or colored in green or in green - yellow; 

 

the blue (or white) core must be connected to the connection point marked with the letter N or colored in black; 

 

the brown (or black) core must be connected to the connection point marked with the letter L or colored  in red. 

 

Working conditions 

 

Ü

 

Working Position 

 

Lighting fixture:

 Max. Tilting 

±

90° from horizontal 

Ü

 

Ambient Temperature, 

t

a

 

at the place of installation and Storage

 

Minimum 10°C, m40°C 

Ü

 

Humidity 

at the place of installation and Storage

 

25-80% (not condensing)

 

Ü

 

Minimum distances from 
inflammable surfaces 

Top 

Back 

Sides 

Front 

0,1 m. 

0,1 m. 

0,1 m. 

0,5 m. 

 
The  luminaire  should  never  be  OPERATED close to inflammable materials. The ones indicated in the above table  are the 
minimum distances recommended. Other requirements for safe use are:

  

 
A.

 

Do not cover the apertures of the luminaire housing. They are essential for correct ventilation.  

B.

 

Use only original accessories and spares from De Sisti Lighting. 

C.

 

Before hanging the luminaire ensure that the suspension point (or the stand) is properly rated to accept the luminaire 
weight. 

D.

 

In case of pole operated use, fit only a P.O. stirrup from De Sisti Lighting. 

E.

 

A suitable secondary safety suspension device (safety cable, chain or equivalent) must be fitted between the suspension 
point and the eyelet at the front of the body . 

 
WARNING : 

DO NOT  MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE . 

 

5.

 

INSTALLATION INSTRUCTIONS 

 

The following procedure should be adopted: 

 

Before connecting the luminaire to the electrical mains ensure that: 

A.

 

Earth line is present on the power socket. 

B.

 

The mains voltage is within the rated range of the luminaire (see technical data on the rating label) 

C.

 

The front safety shield is present and in good condition. 
It consists of a Fresnel lens made by borosilicate un-toughened glass,  
with a Diameter = 120 mm , thickness = 4 mm type ( 3 min ). 

Отзывы: