background image

79 Trenton Avenue, Frenchtown NJ  08825

© Copyright 2018 Designplan Lighting, Inc.

installation instructions

[email protected]

www.designplan.com

P:  908-996-7710

F:  

 

908-996-7042

1 of 

5

INSTRUCTIONS PERTAINING TO RISK OF FIRE OR INJURY TO 

PERSONS.  READ ALL INSTRUCTIONS.  IMPORTANT SAFETY 

INSTRUCTIONS.  SAVE THESE INSTRUCTIONS.

STEP OUTSIDE 

5.1, 5.2, 6.1, 6.2, 

6.3

IP

65

5.X

6.X

Electrical Connections:

• LED lights must be 

connected in series

 respecting polarities.

CHOOSE POWER SUPPLY ACCORDINGLY

.  Please consider the voltage through which fixtures are fed

as well as the max power consumption.

Connect power

 only if all fixtures are connected.

• The power supplies MUST be installed in aerated rooms, far from heat sources. Overworking or lack of air

circulation will not permit natural dissipation.

• The electronic power supply is current-stable, therefore it partially compensates the voltage-drop problems

related to the cable length; we suggest not to exceed 100

 

ft.

• Use only Class 2 type electronic power supply.

• Never use switches on secondary circuit.

  Maintenance

Scheduled maintenance must be carried out once a year on all lighting devices, regardless of appliance 

class and type of use.  It must include the following operations:

• Periodically clean fixtures to remove dirt from gratings and screw heads.

• Check tightness of screws on various parts of the device.

• Check that all cable glands and cables are intact and tight. Check that the glass or plastic 

lens

 is

 

intact,

and replace it if broken or damaged.

• The internal components such as the ballast, 

driver,

 washers and screws must not show clear

 

signs

 

of

oxidation or rust. Clear traces of rust and oxidation will indicate the presence of water inside

 

the

 

device.

• In the case of damage, the components must be replaced by original components or spare parts.

DANGER - RISK OF SHOCK - DISCONNECT POWER BEFORE 

INSTALLATION!  Please read all instructions before installation.  

• Keep these instructions for future reference.

• Must be installed by a qualified electrician in accordance with national and

local standards. Designplan is not responsible for fixtures installed without

regard to these standards.

The main power connection must be in accordance with local electrical

 

codes.

• Unauthorized alterations or tampering of product voids warranty.

• Suitable for 

OUT

DOOR applications.

Remote 500mA

ATTENTION

:

 

For Wall/Ceiling - 

It is the contractor's responsibility to caulk around all the edges between

the fixture and the mounting surface to satisfy wet label requirements.

TM

Содержание STEP OUTSIDE 5.1

Страница 1: ...liance class and type of use It must include the following operations Periodically clean fixtures to remove dirt from gratings and screw heads Check tightness of screws on various parts of the device Check that all cable glands and cables are intact and tight Check that the glass or plastic lens is intact and replace it if broken or damaged The internal components such as the ballast driver washer...

Страница 2: ...sh to the finished floor Housing Installation WC1501 Use 7 12 of drainage gravel check functionality fill tube with water and verify full drainage within 30 min If water remains please utilize a different drainage system that functions properly Contractor to seal the conduit with Great Stuff aerosol seal that prevents water and moisture penetration for ultimate protection It is the contractor s re...

Страница 3: ...wise rotation 5 6 Overall dimensions 4 WC1501 WC1501 4 max 500mA Package Contents STEP 5 1 STEP 5 2 STEP 6 1 STEP 6 2 STEP 6 3 Use corrugated conduit Ø20 minimum recommended Ø25 Use corrugated conduit Ø20 minimum recommended Ø25 Ø 1 77 2 Ø16mm Ø16 x 70 mm 0 63 x 7 09 min 0 197 max 1 18 Ø1 77 1 Use corrugated conduit Ø20 minimum recommended Ø25 2nd 2 Use gel filled waterproof wire nuts for wire con...

Страница 4: ... 996 7710 F 908 996 7042 4 of 5 STEP OUTSIDE 5 1 5 2 6 1 6 2 6 3 Ø2 0 3 0 PPMP03113 In Grade Housing Installation PPMP03113 Drill pilot hole for core drilled housing through wall Connect to driver and install fixture Apply epoxy to sides of newly drilled opening insert core drilled housing into pilot hole and make level POSITON FLUSH WITH THE WALL ...

Страница 5: ...consumption Only power up the system once all the lamps are connected Connecting an individual lamp to an active power supply may cause the lamp to break due to over voltage The electronic power supply is constant current so to a certain extent it automatically compensates the voltage drop associated with cable length however we advise not exceeding 100 feet Lamps and power supply units must be in...

Отзывы: