TB-6511

01/04 Page 1 of 4

Single Wire Multifunction Wrist Strap

Monitor Operation and Maintenance

Figure 1. Item 50513 Single Wire Multifunction Wrist Strap

Monitor

Description

The Desco EMIT 50513 contains all the monitoring

functions required to ensure that the wrist straps,

worksurface, and ground connections of a workstation are

fully functional at all times.

The 50513 continuously monitors:

1. The operator wrist strap for changes in load, or open

circuit

2. The worksurface for resistance 

3. Electrical ground (or earth ground) for continuity and low

resistance 

Installation

Fasten the 50513 with the supplied hook-and-loop self

adhesive strip. The 50513 requires only 4 connections to

work properly: 1) electrical ground, 2) worksurface, 3) single

wire wrist strap, and 4) electrical power. 

GROUND

The electrical ground connection is made through the cord

of the three-wire US/CSA approved AC adapter. Per the

ESD Association ANSI/ESD S20.20, electrical ground is

preferred.

If you are using earth ground, make the connection by

attaching a wire to a water pipe clamp or use an 8" to 12"

copper ground stake. A large number of workstations can

be connected to a single heavy gauge ground wire. Attach

the ground wire to the pin jack adapter on the back of the

unit labeled “GND”. Solder the wire directly to the banana

plug-to-pin jack adapter or use a banana plug on the

ground wire. This pin jack is internally connected to the

banana jack on the front of the unit marked “WRIST

STRAP/GUEST”. This jack may be used as an auxiliary

electrical ground connection point for another piece of

equipment, or as a plug-in point for a wrist strap by persons

visiting the workstation.

Make the worksurface monitoring connection by attaching

two wires to the worksurface. Use “snap” connectors or a

CK-1 contact kit with the two contact points positioned

approximately 1" or less apart. Attach one wire to the pin

jack adapter on the back of the unit labeled “BENCH” and

the other wire to system ground.

Complete the installation by plugging the UL/CSA approved

AC adapter DIN plug into the DIN jack on the rear panel

marked “POWER”, and the adapter into a grounded outlet.

Proper installation is indicated by a red “STRAP” LED, a

green “BENCH” LED, a green “GND” LED, and an

approximately 3 second activation on the audible alarm.

(NOTE: All three LEDs must be green in order to reset

the audible alarm circuit after an alarm condition.)

Wear the single wire wrist strap and plug the cord into the

front panel “WRIST STRAP MONITOR” jack. Observe that

all three green LEDs are on.

Operation

Ground Monitor:

The green “GND” indicator will illuminate when the total

resistance to ground measures less than 100 ohms. Ground

loop resistance greater than 100 ohms will produce a red

“GND” indicator and an audible alarm for approximately 3

seconds.

Check for proper operation by disconnecting the ground

wire from the “GND” terminal or by floating the ground pin

on the power adapter by way of a two-prong to three-prong

adapter (readily available in hardware stores). The “GND”

indicator should illuminate red and the alarm should sound

for approximately 3 seconds when either ground is

interrupted.

DESCO EMIT WEST

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

DESCO EMIT EAST

- 90 Hudson Road, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: http://www.descoemit.com

Made in America

TECHNICAL BULLETIN TB-6511

© 2004 DESCO INDUSTRIES INC.

Employee Owned

Содержание EMIT 50513

Страница 1: ...for a wrist strap by persons visiting the workstation Make the worksurface monitoring connection by attaching two wires to the worksurface Use snap connectors or a CK 1 contact kit with the two contact points positioned approximately 1 or less apart Attach one wire to the pin jack adapter on the back of the unit labeled BENCH and the other wire to system ground Complete the installation by pluggin...

Страница 2: ...ual unit to a particular operator s body capacitance Adjust the unit by removing the top cover of the unit and turning calibration potentiometer R7 until the STRAP indicator just turns red while the operator is wearing the wrist strap Then slowly turn the potentiometer in the opposite direction until the STRAP indicator just returns to green Verify that removing the wrist strap will cause the indi...

Страница 3: ...D lights The value of resistance that causes the BENCH indicator to change from green to red should be 500 k ohm 20 If the trip point is not within this range adjust R21 for a trip point as close to 500 k ohm as possible If the 50513 was special ordered with a different setpoint test and adjust to this special value so that the trip point is within 20 of the special value 4 Set the decade resistor...

Страница 4: ...on MA for a Return Material Authorization RMA and proper shipping instructions and address Include a copy of your original packing slip invoice or other proof of purchase date Any unit under warranty should be shipped prepaid to the Desco EMIT factory Warranty repairs will take approximately two weeks If your unit is out of warranty call Customer Service at 909 627 8178 Chino CA or 781 821 8370 Ca...

Отзывы: