background image

TB-3008

 March 2010 Page 1 of 2

Static Control Smocks
Grounding, Testing and Maintenance

TECHNICAL BULLETIN TB-3008

Figure 1. Desco Static Control Garment

Description

Outfitting a work force in ESD smocks is the single most 
powerful step to demonstrate a company’s commitment 
to their ESD control program. The Desco ESD protective 
smock is designed to be antistatic, low tribocharging, and 
offers protection against electro static fields generated from 
clothing on the user’s body. Using high quality material 
with  minimum 9% carbon nylon monofilament, the smock 
creates a Faraday Cage around the torso of the wearer. 
Static charges generated by the wearer and wearer’s 
clothing will be shielded from ESD susceptible products. 
The dissipative material becomes part of the ground path to 
remove static charges. The smock is jacket length and the 
color is blue.

The smock is constructed of a lightweight dissipative 
material which incorporates texturized polyester and a 
minimum of 9% carbon suffused nylon monofilament. 
The conductive nylon fibers are woven in a chain-link 
design throughout the material, providing continuous and 
consistent charge dissipation. All of the seams in the 
garment are designed to maintain electrical continuity from 
panel to panel and from sleeve to sleeve in accordance with 
the ESD Association Garment Standard, ESD-STM2.1.

The elastic in sleeve end is designed to provide contact of 
dissipative fabric with user’s skin to provide path to ground.

The conductive fabric in smock is a conductor. If not 
grounded, the smock can become an isolated charged 
conductor.

 Since ANSI/ESD S20.20 requires that “All 

conductors in the environment, including personnel, 
must be . . . connected and attached to a known 

DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: 

Desco.com

ground”

, there is no occasion “when grounding the 

garment is not required” in an ESD protected area. If not 
grounded via a wrist strap coil cord, ground ESD garment 
via the person’s wrist removing charges using foot 
grounders, to ESD protective flooring. 

ESD protective economy smocks are available in the 

following sizes:

Size 

Blue 

Chest 

Sleeve

X Small

 

73880

 

30”-32” 

33 3/4”

Small

 

73881

 

34”-36” 

34”

Medium

 

73882

 

38”-40” 

34 3/8”

Large

 

73883

 

42”-44” 

35”

X Large

 

73884

 

46”-48” 

35 1/2”

2X Large

 

73885

 

50”-52” 

35 1/2”

3X Large

 

73886

 

54”-56” 

37 1/2”

4X Large

 

73887

 

58”-60” 

36 1/2”

5X Large

 

73888

 

62”-64” 

36”

6X Large

 

73889

 

66”-68” 

36”

Installation

Follow the directions below for proper installation and 
grounding of the ESD smock.

1. Put on the smock and fasten all of the snaps on the front 
of the smock, making sure that clothing is not exposed 
outside of the smock.

2. Make sure the elastic in sleeve cuff is snug on your wrist.  
Place a wristband on your wrist. Connect a grounded coil 

cord to the wristband. (Alternatively, foot grounders and 

ESD protected flooring can provide path to ground.)

The user and the smock will now be properly grounded. The 
user needs to verify that the smock is grounded through 
skin contact.

NOTE: ANSI/ESD S20.20 REQUIRES THAT THE 
GROUND CORD SELECTED FOR GROUNDING OF 
PERSONNEL CONTAIN A BUILT-IN CURRENT LIMITING 
1 MEGOHM RESISTOR.  

YES!

NO!

YES!

NO!

© 2010 DESCO INDUSTRIES INC.

Employee Owned

Figure 2. Proper installation of smock on wearer’s body