background image

TB-2040

 October 2013 Page 1 of 6

Combo Wrist Strap / Footwear Tester

Installation, Operation and Maintenance

Pass Range 750K - 10M and 750K - 100M

DESCO WEST

 - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 

DESCO EAST

 - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

Figure 1. Desco 

19250

 Combo Tester

Description

The Desco 

19250

 Combo Tester is a 3-state touch tester 

designed for fast, frequent testing of ESD personnel grounding 

devices. This product can be used as one of the tools to fulfill the 

ANSI ESD S20.20 paragraph 6.1.3.2 “Compliance Verification 

Plan. Verification should include routine checks of the Technical 

Requirements of the Plan.” The Combo Tester incorporates a 

unique dual test circuit design which improves accuracy of testing 

and eliminates the need for separate wrist strap and foot grounder 

test units. The 

19250

 is equipped with a 750 kilohm - 10 megohm 

circuit, ideal for testing of wrist straps and a 750 kilohm - 100 

megohm circuit designed for accurate testing of footwear. 
Test parameters are factory set but can be adjusted to match your 

own specifications. The 

19250

 is very simple to operate. A green 

light signals the user that everything is OK. A red light and an 

audible indicator means that the circuit resistance is either too low 

or too high.
The Tester operates on either a 9 volt battery or a special AC 

adapter. The Combo Tester is calibrated to NIST traceable 

standards and is available in three models.

a continuous, reliable ground is needed, and then continuous 

monitoring should be considered or even required.”

Per ESD SP9.2 APPENDIX B - Foot Grounder Usage Guidance

“Compliance verification should be performed prior to each use 

(daily, shift change, etc.). The accumulation of insulative materials 

on the FCS may increase the foot grounder system resistance. If 

foot grounders are worn outside the ESD protected area testing for 

functionality before reentry to the ESD protected area should be 

considered.”

Per ESD SP9.2 APPENDIX C -Parallel Ground Paths

“A parallel ground path allows a flow of electrical current through a 

path that is not intended for the test. Parallel ground paths may be 

caused by several different situations.

For example:

a.  The path represented by the person standing with one shoe on 

the floor and the other shoe on the test apparatus. A parallel 

path may be created by the shoe on the floor. Current from the 

test instrument is then directed down two paths when it was 

intended to be directed down one. The correct path for the test 

is with one shoe in the air or on an insulating surface and the 

other shoe on the test plate.

b.  The path presented by a person inadvertently supporting 

themselves by means of one hand on another object such as 

a wall, table or supporting member in order to measure the 

resistance in one foot contact. The hand has created a parallel 

path to ground.

c.  The path represented by a person leaning against another 

object with other parts of the body in order to provide physical 

support during a testing sequence. This can then lead to other 

grounding paths and erroneous results.”

Packaging

Remove the Tester from the carton and inspect for damage. 
Items included with model 

19250

:

1 Combo Tester 

1 9 volt battery
Items included only with model 

19253

:

1 Combo Tester 

1 Foot plate

1 Ground cord

1 9 volt battery
Items included only with model 

19252

:

1 Combo Tester

1 Base plate

1 Pedestal tube with bracket and boot installed

1 4” banana plug connector

1 Vinyl insulator cap

1 Wall poster

1 5/32” hex wrench

1 9 volt battery
Model numbers 

19253

 and 

19252

 are ideally suited for testing foot 

grounding devices.

TECHNICAL BULLETIN TB-2040

Made in the

United States of America

© 2013 DESCO INDUSTRIES INC.

Employee Owned

CAUTION: Use only the AC adapter designed for this unit: 

Item 

98256

 (120 volt) or Item 

98257

 (220 volt). Using any other 

adapters may damage the unit and void the warranty.
Per ESD Handbook ESD TR20.20 paragraph 5.3.2.4.4 Test 

Frequency “Typical test programs recommend that wrist straps 

that are used daily should be tested daily. However, if the products 

that are being produced are of such value that knowledge of 

Model    Description

19250

    Combo Tester, 9 Volt battery 

19253

    Combo Tester w/ FOOT PLATE

19252

    Combo Tester w/ Stand 

19261

    Combo Tester Mounting Plate

98273

    Foot Plate for Combo Tester

98254

    Stand for Combo Tester

98256

    AC Adapter, 120V

98257

    AC Adapter, 220V

Содержание 19250

Страница 1: ...ot intended for the test Parallel ground paths may be caused by several different situations For example a The path represented by the person standing with one shoe on the floor and the other shoe on the test apparatus A parallel path may be created by the shoe on the floor Current from the test instrument is then directed down two paths when it was intended to be directed down one The correct pat...

Страница 2: ...ct out more than 1 4 from mounting surface The template on page four is actual size 2 Mount the Tester on the screws pulling down to lock it in place Figure 3 Stationary installation of the Combo Tester Operation The Combo Tester can be operated either on battery or AC power The unit comes equipped with a 9 volt alkaline battery For AC operation plug the optional AC adapter into the mini phone jac...

Страница 3: ...HI LEDs light and the audible indicator sounds the wearer should check the foot grounding device immediately 8 Repeat steps 3 6 with other foot Free Standing Test Fixture Assembly and Operation Model 19252 The 19252 s rugged steel pedestal tube is powder coated in a non conductive white finish that helps to prevent false readings if contacted by skin or loose smocks 3 Open the compartment and atta...

Страница 4: ...st be calibrated individually Desco offers a calibration unit that is specifically designed to simplify the calibration procedure This unit is sold as item 07010 The Calibration Unit comes calibrated to NIST traceable standards For additional information on the 07010 ask for Technical Bulletin TB 2039 750 Kilohm 10 Megohm TEST RANGE WRIST STRAPS The following resistance should give the display sho...

Страница 5: ...switch as in step 1 The red FAIL HI LED should illuminate The FWH trimpot may require a slight re adjustment 6 Re check to insure that all footwear ranges are correct RETURN UNIT TO SERVICE Unauthorized modifications will void the product warranty Servicing should be performed only at the factory See warranty section for repair information Specifications Wrist Strap Circuit FAIL HI Factory set at ...

Страница 6: ...ns and address Desco will quote repair charges necessary to bring your unit up to factory standards Warranty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESSED AND IMPLIED INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED The express warranty will not apply to defects or damage due to accidents neglect ...

Страница 7: ... 401 Building No 5 JiuGe Business Center Lane 2301 Yishan Rd Minhang District Shanghai China Sales Direct 86 21 6401 6692 Email amall ameya360 com QQ 800077892 Skype ameyasales1 ameyasales2 Customer Service Email service ameya360 com Partnership Tel 86 21 64016692 8333 Email mkt ameya360 com ...

Отзывы: