5.  Press in control knob and turn counter

-

clockwise 

 to the PILOT position. 

Keep control knob pressed in for five (5) 

seconds (see Figure 31).

 

Note:

 You may be running this heater for 

the first time after hooking up to gas sup

-

ply. If so, the control knob may need to be 

pressed in for 30 seconds or more. This will 

allow air to bleed from the gas system.

6.  With control knob pressed in, press and 

release ignitor button. This will light pilot. 

The pilot is attached to the front burner. If 

needed, keep pressing ignitor button until 

pilot lights.

 

Note:

  If  pilot  does  not  light,  contact  a 

qualified service person or gas supplier for 

repairs. Until repairs are made, light pilot 

with match. To light pilot with match, see 

Manual Lighting Procedure

7.  Keep control knob pressed in for 30 seconds 

after lighting pilot. After 30 seconds, release 

control knob.

• If control knob does not pop out when 

released, contact a qualified service person 

or gas supplier for repairs.

 

Note:

 If pilot goes out, repeat steps 3 

through 7. 

8.  Push in and turn control knob counterclock-

wise 

 to the HI position. Both burners 

should light. Set control knob to desired 

setting. 

9.  To leave pilot lit and shut off burners only, 

turn control knob clockwise 

 to the 

HI position then press in and turn clockwise 

 to PILOT position.

OPERATING HEATER

Continued

Figure 32 - Pilot

Ignitor 
Electrode

Thermocouple

Pilot 
Burner

Figure 31 - Control Knob and Ignitor 

Button Location

Control Knob

Ignitor Button

vARIABLE CONTROL 

OPERATION

The variable control valve can be set to any heat 

setting and flame height desired, by simply turn

-

ing the control knob until that setting is attained. 

Even the lowest setting provides realistic flames 

and glowing embers from two burners. Selecting 

higher settings produces greater heat output. 

This results in increased heating comfort.

  WARNING:  Do  not  operate 

heater between locked positions.

 CAUTION: Do not try to ad-

just heating levels by using the 

equipment shutoff valve.

TO TURN OFF GAS 

TO APPLIANCE

Shutting Off Heater

1.  Press in and turn control knob clockwise 

 to the HI position.

2.  Turn the control knob clockwise 

 to 

the PILOT position.

3.  Press in control knob and turn clockwise 

 to the OFF position. 

4.  Close equipment shutoff valve (see Figure 

18, page 16).

MANUAL LIGHTING 

PROCEDURE

1.  Follow steps 1 through 5 under 

Lighting 

Instructions

, page 21.

2.  Depress control knob and light pilot with 

match. 

3.  Keep control knob pressed in for 30 seconds 

after lighting pilot. After 30 seconds, release 

control knob. Now follow step 8, column 1.

Содержание R 18" Remote-ready

Страница 1: ...urgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied inst...

Страница 2: ...agency or the gas supplier WARNING This appliance is for installation only in a solid fuel burning mason ry or UL127 factory built fireplace or in a listed vent less firebox enclosure It is design ce...

Страница 3: ...eep this manual for reference It is your guide to safe and proper operation of this heater WARNING Any change to this heater or its controls can be dangerous WARNING Do not use a blower insert heat ex...

Страница 4: ...Deple tion Sensing ODS safety shutoff system The ODS shuts down the heater if enough fresh air is not available See Air for Combustion and Ventilation page 6 If heater keeps shutting off see Troubles...

Страница 5: ...nt or up a chimney Heat is generated by both realistic flames and glowing coals This heater is designed for vent free operation with flue damper closed It has been tested and approved toANSI Z21 11 2...

Страница 6: ...Includes the room in which you will install heater plus any adjoining rooms with doorless pas sageways or ventilation grills between the rooms 1 Determine the volume of the space length x width x hei...

Страница 7: ...Your options are as follows A Rework worksheet adding the space of an adjoin ingroom Iftheextraspaceprovidesanunconfined space remove door to adjoining room or add ventilation grills between rooms Se...

Страница 8: ...n out doors located on floor or wall of fire place If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper WARNING Never install the heater in a...

Страница 9: ...Wall Example NOTICE Manual control heaters maybeusedasaventedproduct Ifso youmustalwaysrunheater with chimney flue damper open If running heater with damper open noncombustible material above fireplac...

Страница 10: ...e fireplace opening Noncombustible materials such as slate marble tile etc must be at least 1 2 thick With sheet metal you must have non combustible material behind it Noncombustible material must ext...

Страница 11: ...of Mantel Shelf Mantel Shelf Floor Clearances A If installing appliance on the floor level you must maintain the minimum distance of 14 to combustibles see Figure 8 B If combustible materials are les...

Страница 12: ...NING If installing in a sunken fireplace special care is needed You must raise the fireplace floor to allow access to heater control panel This will insure adequate air flow and guard against sooting...

Страница 13: ...inued Heater Gas Regulator Flexible Gas Hose if allowed by local codes Figure 11 Attaching Flexible Gas Hose to Heater Gas Regulator Variable Manually Controlled and Thermostatically Controlled Models...

Страница 14: ...the installer must supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 inches of water If you do not reduc...

Страница 15: ...ptional CSA design certified equipment shutoff valve from your dealer See Accessories page 42 Minimum inlet pressure for purpose of input adjustment Figure 17 Gas Connection Remote Ready Models Only G...

Страница 16: ...e for natural gas or propane LP supply to equipment shutoff valve for propane LP see Figure 19 or 20 Apply noncorrosive leak detection fluid to all joints Bubbles form ing show a leak 4 Correct all le...

Страница 17: ...Receiver Figure 22 Installing Remote Receiver Front Back Insulating Washers Remote Receiver Mounting Clips Front Back Wires Nut Nut Screw White Wire From Receiver Installation Continued Front Back ins...

Страница 18: ...s in the back of the rear log 3 against the rear grate prongs Make sure the log fits securely over the prongs see Fig ure 28 Make sure log is completely vertical and not leaning in toward burner where...

Страница 19: ...ce and to replace any part of the control system and any gas control which has been under water lighting instructions WARNING If fireplace has glass doors never operate this heater with glass doors cl...

Страница 20: ...rclockwise to desired heating level The burners should light Set control knob to any heat level between HI and LO 9 To leave pilot lit and shut off burners only turn control knob clockwise to the PILO...

Страница 21: ...ol system and any gas control which has been under water Operating Heater Continued lighting instructions WARNING If fireplace has glass doors never operate this heater with glass doors closed If you...

Страница 22: ...ave pilot lit and shut off burners only turn control knob clockwise to the HI position then press in and turn clockwise to PILOT position Operating Heater Continued Figure 32 Pilot Ignitor Electrode T...

Страница 23: ...the control system and any gas control which has been under water Operating Heater Continued lighting instructions WARNING If fireplace has glass doors never operate this heater with glass doors clos...

Страница 24: ...goes out repeat steps 4 through 8 page 19 9 Slightly push in and turn control knob coun terclockwise to the ON position 10 Wait one minute and switch selector switch to the ON position to light burner...

Страница 25: ...gure 36 Setting the Selector Switch Control Knob and Flame Adjustment Knob for Remote Operation On Off Series Model HRC100 Hold the control button on the hand held remote until burner turns on Hold th...

Страница 26: ...pilot flame pattern Figure 39 shows a correct pilot flame pattern Figure 40 shows an incorrect pilot flame pattern The incorrect pilot flame is not touching the thermocouple This will cause the therm...

Страница 27: ...r inspected yearly by a qualified service person Heater may need more frequent cleaning due to excessive lint fromcarpeting pethair bedding material etc WARNING Failure to keep the primary air opening...

Страница 28: ...a drinking straw if compressed air is not available CLEANING AND MAINTENANCE Continued Figure 43 Injector Holder On Outlet Burner Tube Burner Tube Injector Holder Primary Air Inlet Holes Ports Slots F...

Страница 29: ...in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct OBSERVED PROBLEM When ignitor button is pressed there is no spark at ODS pilot When igni...

Страница 30: ...Contact local natural or pro pane LP gas company 2 Clean burner s see Cleaning and Maintenance page 27 or replace burner orifice s 3 Contact qualified service person 1 Clean burner see Cleaning and M...

Страница 31: ...into white powder residue 1 Not enough combustion ven tilation air 1 Battery is not installed Bat tery power is low 1 Metal expanding while heat ing or contracting while cooling REMEDY 1 Check burner...

Страница 32: ...ween con trol valve and burner 2 Gas leak See Warning statement at top of page 1 Thermostat sensing bulb needs to be repositioned Thermostat Controlled Models Only 2 Hand held remote control is too cl...

Страница 33: ...ew after removing the thermostat sensing bulb IMPORTANT Do not force or bend the thermostat sensing bulb or capillary 3 The thermostat sensing bulb may be located to the lower right front side of fire...

Страница 34: ...ve further questions about installation operation or troubleshooting If so contact DESA Heating Products Technical Service Department at 1 866 672 6040 When calling please have your model and serial n...

Страница 35: ...let Gas Pressure in of water Maximum 14 10 5 14 10 5 14 10 5 Minimum 11 5 11 5 11 5 Shipping Weight 30 lbs 30 lbs 30 lbs For purpose of input adjustment 30 Thermostat 30 Variable 30 Remote Ready Contr...

Страница 36: ...18 18 26 6 2 6 1 24 25 22 21 9 10 12 11 13 14 4 25 25 8 6 20 7 19 3 5 1 36 Models 1 18 24 30 Models 2 Illustrated Parts Breakdown Variable Manually Controlled split oak Models nvs18NV nvs18PV nvs24NV...

Страница 37: ...n 1 15 098508 01 098508 01 098508 01 098508 01 Valve Retainer Pin 1 16 102568 01 102568 01 102568 01 102568 01 Gas Valve NG 1 102568 02 102568 02 102568 02 102568 02 Gas Valve LP 1 17 101005 01 101005...

Страница 38: ...ted parts breakdown Thermostat controlled Models nvs18NT nvs18PT nvs24NT nvs24PT nvs30NT nvs30PT nvs36NT and nvs36PT 3 2 1 36 Models 1 18 24 30 Models 8 9 24 10 23 5 29 9 2 9 1 6 7 26 12 13 15 14 16 4...

Страница 39: ...8354 01 098354 01 098354 01 Control Knob 1 16 102013 01 102013 01 102013 01 102013 01 Control Rod 1 17 100000 01 100000 01 100000 01 100000 01 Cotter Pin 1 18 101053 01 101053 01 101053 01 101053 01 A...

Страница 40: ...parts breakdown remote ready variable control models nvs18nr nvs18pr nvs24nr nvs24pr nvs30nr nvs30pr nvs36nr and nvs36pr 22 12 13 20 19 14 21 17 18 16 23 4 15 27 25 5 28 29 26 5 7 8 10 9 1 9 2 7 9 5 6...

Страница 41: ...103782 01 103782 01 Valve Bracket 1 16 M12461 26 M12461 26 M12461 26 M12461 26 Screw 5 17 103781 01 103781 01 103781 01 103781 01 Gas Control NG 1 103781 02 103781 02 103781 02 103781 02 Gas Control L...

Страница 42: ...HRC200 For all Remote Ready Models Allows the fire place to be operated in a manually or thermostati cally controlled mode You can turn the fireplace on and off without ever leaving the comfort of yo...

Страница 43: ...NON circulating Not Shown For all models damper CLAMP GA6080 Not Shown For Remote Ready and Variable Manually Controlled Models Permanently opens chimney flue damper for vented operation lava rock GA6...

Страница 44: ...The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condit...

Отзывы: