When wiring to additional standard
fixture only:
Strip the motion sensor's
red
wire and connect to the standard
light's
black
wire. Connect all white wires
together. Total fixture ratings must not
exceed 500 Watts (4.1 A.).
Note: All wiring between fixtures should
be run in accordance with the National
Electrical Code through conduit or another
acceptable means.
Contact a qualified
electrician if there is any question as
to the suitability of the system.
BLACK
RED
WHITE
(Standard)
Wiring to Motion Light &
Standard Fixture
OPTIONAL WIRING
❒
This fixture is provided with a sensor rated
for 500 Watts. Since the fixture is only
rated 100 Watts, 400 Watts of additional
load may be controlled by this sensor.
❒
When determining what a fixture is rated
for, do not simply look at the rating on the
lamp in the fixture. Look at the marking
which specifies the maximum lamp watt-
age for which the fixture is suitable.
❒
Once you have selected the fixtures to be
connected and determined their maximum
ratings, add these ratings up. For instance,
if you have 3 fixtures rated 100 Watts, 150
Watts, and 75 Watts respectively, you have
a total load of 325 Watts.
BLACK
WHITE
BLACK
Master
Slave
Wiring to Control One Motion Sensing
Lantern (Slave) from Another (Master)
It is also possible to wire two motion sensing coach lights so that either unit will turn on
both lights at the same time (dual master system). It is recommended that only people with
plenty of electrical experience attempt this configuration. Please call our customer service
number (1-800-858-8501 - English Speaking Only) before attempting this wiring.
If the dual
master wiring is not done correctly, it can destroy both motion sensing fixtures and
void your warranty.