5.5
Troubleshooting
FAULT
DETECTED
POSSIBLE
CAUSE
SOLUTION
RECOMMENDED
The vacuum cleaner
will not start
-
No electric supply
-
Check for the presence of
voltage in the socket
-
Check the integrity of the socket
and the cable
-
Contact DEPURECO’s technical
assistance
-
Red indicator light
on (Maximum tank
capacity reached)
-
Empty the tank
Insufficient vacuuming
power
-
Grid basket a/o PPL
washable filter
clogged
-
Clean the filter and the grid
basket
Liquids come out of the
vacuum cleaner
-
Fastening clamp not
correctly fastened
-
Close the clamp completely
-
Faulty ball valves
-
Replace ball valves