21
11.2. Error in the screwdriving sequence
Number Meaning
Troubleshooting
E01
The pre-set monitoring time of the screwdriving
step was exceeded.
E02
The pre-set minimum angle of the screwdriving
step was not reached.
E03
The pre-set maximum angle of the screwdriv-
ing step was exceeded.
E04
The pre-set minimum torque of the screwdriv-
ing step was not reached.
E05
The pre-set maximum torque of the screwdriv-
ing step was exceeded.
Check the screwdriving procedure
and adapt if necessary.
E06
An invalid program was transferred to the
power unit.
Check the program and transfer it
again.
...
-
-
E08 -
-
E09
Program is not valid (does not exist or was
created for a different screwdriver)
Check the program, adapt if neces-
sary or select a different program.
E10
The start signal was restored before the normal
end of screw assembly.
The start signal must register at the
end of screw assembly.
E11
Power exceeds the maximum permissible
value.
Check the screwdriving procedure
and adapt if necessary.
Contact the DEPRAG service de-
partment with any queries.
...
-
-
E13
Error in writing the program
Transfer the program again.
E14
Power unit not initialized with screwdriver data
Switch the DEPRAG MINIMAT®–E
D
screwdriver off and on again.
...
-
-
E18
Overload of the tool over a defined time period
Check the screwdriving procedure
and adapt if necessary.
Contact the DEPRAG service de-
partment with any queries.
...
-
-
E21
Screw assembly ended because the power unit
was switched off.
Please contact the DEPRAG service
department.
Tables 7:
Error in the screwdriving sequence