Trouble
Cause
Remedy
Loose or disconnected wires
Visually check and repair
Poor contacting at wire terminal
Pull the lead wire and check connection
Generator
Replace
Control device (FE-50)
Replace
Transistor(IGBT)
Replace
Rectifier (Re1)
Replace
Current regulator(VR
1
)
Replace
DC reactor
Replace
Condenser(C
1
,
2
)
Replace
Inadequate length or thickness of
welding cable
Replace
No arcing or weak
arcing
Output terminals
Replace and Repair
Loose or disconnected wires
Visually check and repair
Poor contacting at wire terminal
Pull the lead wire and check connection
Control device (AVR)
Replace
Rotor
Replace
Engine speed is too low
Adjustment and repair
Circuit breaker
Replace
No AC output
Layer short-circuit in armature
Replace
Loose or disconnected wires
Visually check and repair
Poor contacting at wire terminal
Pull the lead wire and check connection
No flow of fuel
Check fuel tank and fuel filter and
the water separator and remove foreign
matter Change filter, if clogged inside
Air or water in fuel system
Bleed air
Fuel cock / water separator cock closed Open fuel cock / water separator cock
Over discharged battery
Charge or replace
Starter switch
Replace
Starter
Replace
Broken pre-heat circuit
Repair
Burned fuse(F3 5A, main fuse 65A)
Replace
Emergency unit
Replace
Engine does not
start
Safety relay
Replace
.