(6) Check grounding for electric shock protection
Make sure that the case grounding of the machine and the
load are certain.
Do not ground directly ГOJ terminal.
(7) Check for leak of water and oil
Check the machine for the trace of leak of oil or water. If a
leak is found, check the location of leak and stop it.
When the leak cannot be stopped, contact our service factory.
(8) Check for loose parte
Check for loose bolts and nuts. Loose parts should be tightened firmly. Particularly,
make check on (the fitting of air cleaner, muffler, turbo-charger, etc.), disconnection
of electric wiring, short-circuit and loose terminals.
(9) Removal of foreign objects in machine
* Check that tools and cleaning cloth are not left in the machine. Remove if
necessary. .
* Check the surroundings of the muffler and engine for presence of dust and
flammable objects. Remove if necessary.
*
Check that the cooling air inlet and the cooling air outlet of the machine are not
clogged with dust or other objects. Remove if necessary.