6 Operation
Dentsply Sirona
6.1 Referencing run
Operating Instructions inLab MC X5
6
Operation
6.1
Referencing run
The referencing run is used for the function check of the detection system
and the position check of moving parts in the processing chamber. The
referencing run takes place automatically via the firmware. The complete
referencing run always takes place following switch-on of the machine
immediately before starting the first job. The shortened referencing run
takes place before every new job.
NOTICE
Observe the Operator’s Manual
Please also observe the information in the Operator's Manual for inLab
CAM SW software.
NOTICE
Ensuring the workpiece holder position
The workpiece holder possesses two moving axes. In the manual
adjustment of the position, it must be ensured before every referencing
run that the workpiece holder is in the horizontal position, i.e. level with
the clamp of the support arm. The machining chamber lighting then
switches to white.