9. Availability
Description
straight legs
bent legs
Quantity
palex
®
Mini – 7
(Expansion 7 mm)
602-800-11
602-800-31
602-800-55
602-801-11
602-801-31
602-801-55
1 piece
10 pieces
50 pieces
palex
®
Medium – 10
(Expansion 10 mm)
602-808-11
602-808-31
602-808-55
602-840-11
602-840-31
602-840-55
1 piece
10 pieces
50 pieces
palex
®
Maxi – 12
(Expansion 12 mm)
602-811-11
602-811-31
602-811-55
602-812-11
602-812-31
602-812-55
1 piece
10 pieces
50 pieces
Packages (1 piece / 10 pieces): with 1 / 10 safety key(s)
Packages (50 pieces): with 1 safety key
Safety key
611-120-00
10 pieces
Universal bending tool
611-122-00
1 piece
10. Quality information
Dentaurum guarantees the perfect quality of its products. These
recommendations are based upon Dentaurum´s own experiences. The user is
solely responsible for the processing of the products. Responsibility for failures
cannot be taken, as we have no influence on the processing on site.
11. Explanation of symbols used on the label
Please refer to the label. Additional information can be found at
www.dentaurum.com (Explanation of symbols REF 989-313-00).
Information for the doctor / patient
Before the palex
®
appliance is cemented into position, turn the spindle (screw)
slightly 2 – 3 quarter turns in the direction of the arrow to test the function.
Then turn back to the original position.
Turn the palex
®
screw only in the direction of the arrow. Opening and closing
the screw several times during the treatment can cause its malfunction. The
finished palex
®
appliance is cemented into position in the usual manner. Please
observe the instructions from the cement manufacturer.
Following this, the screw is turned four times by 90° using the blue
safety key (REF 611-120-00) for this purpose. One full 360° turn of the
spindle = 0.8 mm expansion.
The patient should turn the screw two times by 90° both in the morning and
evening (according to your in structions) until the desired expansion is achieved.
#
Important:
Use only the blue safety key supplied, as this cannot accidentally
be swallowed.
Regular visits are recommended to monitor progress.
The palex
®
appliance is secured against unwanted turning-back, after the
desired degree of expansion is achieved, by fitting a ligature or blocking
with acrylic. For stabilization the appliance should remain in the mouth for
approximately 2 – 3 months.
A retainer should be worn following removal of the palex
®
appliance.
The product should not be used, if there is a known allergic reaction
to one or more of the material components.
Instructions for use
palex
®
screws
(Biederman)
US
989-516-21
Printed by Dentaurum Germany 10/18/B/R1-22
Â
Â
For more information on our products,
please visit www.dentaurum.com
Â
Â
Our orthodontic technicians are available to answer
any questions you may have regarding our products:
Customer Service: Phone 800 523 3946
Date of information: 10/18
Subject to modifications
Dentaurum Inc. | 2050 Cabot Boulevard West, Suite 100 | Langhorne, PA 19047 I USA
Phone + 1 - 800 - 523 - 3946 I Fax + 1 - 800 - 553 - 6389 | www.dentaurum.com I [email protected]