Denso GT10Q-SU Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2D Code Handy Scanner 

GT10Q-SU / GT11Q-SU 
GT10Q-HU / GT11Q-HU 

User's Manual

 

Содержание GT10Q-SU

Страница 1: ...2D Code Handy Scanner GT10Q SU GT11Q SU GT10Q HU GT11Q HU User s Manual...

Страница 2: ...he use of DENSO WAVE s product s in connection or in combination with other component s product s data processing system s or equipment or software not supplied from DENSO WAVE ii the use of DENSO WAV...

Страница 3: ...4 Chapter 8 Scanning Functions 26 8 1 Data verification mode 26 8 1 1 Verification setup procedure 26 8 1 2 Specifying a verification object 27 8 1 3 Verification result output 28 8 2 Editing data 29...

Страница 4: ...ine 59 11 2 Image capturing specifications 59 Chapter 12 Parameters and Defaults 61 Chapter 13 QR Coded Parameter Menu 73 13 1 Parameter setting procedure using the QR coded parameter menu 73 13 2 QR...

Страница 5: ...n environment with electrical noise that can trigger malfunction Note Specifications described in this manual are supported by GT10Q Firmware version 2 00 or later Note The shape of the projected area...

Страница 6: ...conditions which could cause serious bodily injury or death if the instructions are not followed correctly Alerts you to those conditions which could cause minor bodily injury or substantial property...

Страница 7: ...into contact with the terminals in connectors Doing so could produce a large current through the scanner resulting in heat or fire as well as damage to the scanner Never use the scanner on the line vo...

Страница 8: ...g resulting in a fire Always use the scanner in a well ventilated area Do not scratch or modify the scanner or its interface cable Do not bend twist pull or heat the cable Doing so could damage the sc...

Страница 9: ...areas therefore periodically check the clear plate and clean it if dusty To clean the plate first blow the dust away with an airbrush Then wipe the plate with a cotton swab or the similar soft one gen...

Страница 10: ...his window to a code to be scanned Magic key Acts as an auxiliary key for scanning or transferring data Refer to Chapter 7 for details Indicator LED Illuminates in blue when the scanner has read a cod...

Страница 11: ...witch between the USB COM interface and USB keyboard interface by using the QR coded parameter menu provided in Chapter 13 or the configuration software ScannerSetting_2D To use the USB COM interface...

Страница 12: ...ow hold the scanner body align the mark on the cable connector with that on the scanner and fully insert the interface cable connector 3 Align the two bosses on the connector cover with cutouts in the...

Страница 13: ...B COM device driver and uninstaller which are compressed It is a self extracting file Store the file into a folder and then double click its icon to extract it Connecting the USB interface cable to th...

Страница 14: ...rivers Dwport sys 3 Reboot the host computer If you attempted to install the device driver designed for Windows 98 family to Windows 2000 XP Windows 2000 XP issued an error and rejected the driver ins...

Страница 15: ...port number to be changed at the time of next rebooting of the host computer if 1 you have connected the scanner to the COM port first time or 2 you have changed the configuration as given below Chan...

Страница 16: ...dows 98SE 2 Double click the driver icon to extract it 3 Connect the scanner s USB interface cable to the computer or USB hub and the New Hardware Found appears 4 The Add New Hardware Wizard starts Cl...

Страница 17: ...Found messages for Unknown device and DENSO WAVE USB COM Port appear in this order All installation processes are completed 10 To make sure that the USB COM device driver has been successfully install...

Страница 18: ...e located or click Browse to specify it and then click Next NOTE Do not specify any folder other than WIN9X Doing so may affect the system badly NOTE This sample assumes that the drivers have been ext...

Страница 19: ...emove this driver with the uninstaller reboot your computer and perform the above connection process again Windows 2000 1 Switch your computer on to run Windows 2000 Log on as an Administrator 2 Doubl...

Страница 20: ...y affect the system badly NOTE This sample assumes that the drivers have been extracted in D DRIVER You need to specify the folder where you have actually extracted the drivers 8 Wait for the screen s...

Страница 21: ...t added or it is marked with or remove this driver with the uninstaller reboot your computer and perform the above connection process again Windows XP 1 Switch your computer on to run Windows XP Log o...

Страница 22: ...may affect the system badly NOTE This sample assumes that the drivers have been extracted in D DRIVER You need to specify the folder where you have actually extracted the drivers 6 Even if the cautio...

Страница 23: ...s Device Manager If DENSO WAVE USB COM Port is added to the sub tree of Ports COM LPT as shown at left the scanner is connected normally If the device is not added or it is marked with or remove this...

Страница 24: ...ection 13 1 Connecting the USB interface cable to the host s USB port or USB hub automatically runs the system supplied driver setup wizard Follow the wizard and set up the driver The setup procedure...

Страница 25: ...Windows 8 To check whether the USB device is working normally open the Windows Device Manager If USB Human Interface Device is added to the sub tree of Human Interface Devices as shown at left the sca...

Страница 26: ...ice is working normally The scanner is designed to work with the default device driver of Windows Me but the device name is not officially registered to the driver so the device is marked with an Ther...

Страница 27: ...anner Upon completion of the configuration the screen shown at left automatically disappears 4 To check whether the USB device is working normally open Windows Device Manager If USB Human Interface De...

Страница 28: ...when the multi line code scanning is allowed If two or more codes fall within the scan range at the same time the scanner may fail to read or read those codes in alternation Note The scanner can read...

Страница 29: ...symbols in the QR coded parameter menu by pressing the trigger switch The QR coded parameter menu is given in Chapter 13 2 Using the configuration software ScannerSetting 2D in your computer The conf...

Страница 30: ...successfully the illumination LEDs go off and the scanner switches to standby 3 Alternate switching mode Each time you press the trigger switch the scanner toggles between the ready to scan and standb...

Страница 31: ...control the scanner by sending scanning control commands from the host computer via the USB interface instead of pressing the trigger switch Scanning control commands include R READON LON Z READOFF an...

Страница 32: ...same range These LEDs go off when a code label is moved away from the range or stays within the range without move for approx 3 seconds The scanner offers a choice of three sensitivity levels for resp...

Страница 33: ...r since the last read operation 3 Specific character transfer function Pressing the magic key transfers a character sequence max 10 bytes specified with the configuration software ScannerSetting_2D 4...

Страница 34: ...ctions listed above the magic key has the following functions that are independent of the above ones Temporarily canceling the barcode reader mode Selecting the barcode reader mode see Chapter 8 Secti...

Страница 35: ...een 2 With the magic key held down press the trigger switch to read the master code to be registered The scanner operates in the trigger switch operating mode currently set During the registration ope...

Страница 36: ...ification start position No of characters to be verified Data string read Verification object Result 345 3 3 00345 Match 345 3 3 00345678 Match 345 3 3 00346 Mismatch 345 3 3 0034 Mismatch 2 Data bloc...

Страница 37: ...r LED OK vibrations NG vibrations If there is a match Emits a short beep Lights in blue Operates If there is a mismatch Emits a long beep Lights in red Operates 3 Scan lock The scan lock function lock...

Страница 38: ...2 1 1 Extracting a data string The scanner extracts a data string specified by the Extraction start position and Extraction end position from a code specified by the Code type and then outputs it in t...

Страница 39: ...h position Error 6th position Tail position Error 6th position By 10 positions Error Code type QR Code Data transfer regardless of error result Prohibit 1st position 6th position Error Head position 6...

Страница 40: ...Extraction conditions Choices Any code QR Code PDF Data Matrix MaxiCode UPC A EAN 13 UPC E EAN 8 Code 128 EAN 128 Codabar NW 7 Code 39 Interleaved 2of5 ITF RSS Code type EAN UCC Composite symbology D...

Страница 41: ...0 2 and 5 STX ETX STX 7890 ETX 1 23 456 7890 5 Error 1 23 456 7890 4 and 5 Error Code type QR Code Data transfer regardless of error result Prohibit 1234567890 1 and 2 Error 1 23 456 7890 5 STX 1 23...

Страница 42: ...ID mark can be also added to each element string if their transmissions are enabled The number of digits is the count of each element string edited Example Data read 01 94901234567894 11 030808 13 03...

Страница 43: ...40208 ETX 17 11 STX 040208 030808 ETX 17 17 STX 040208 040305 ETX 12 01 12 Data transfer regardless of error result Permit 01 01 Comma STX 0194901234567894110308081303081017 04020817040305 ETX Note 1...

Страница 44: ...Extraction conditions Data read Output data 0194901234567894110308081303 081017040208 STX 01 94901234567894 11 030808 13 03 0810 17 040208 ETX Data transfer regardless of error result Prohibit 0194901...

Страница 45: ...e YYMMDD 20 n2 n2 Product Variant 21 n2 an 20 Serial Number 22 n2 an 29 HIBCC Health Industry Business Communication Council Quantity Date Batch and Link 23n n3 n 19 Batch or Lot Number Transitional U...

Страница 46: ...34n n4 n6 Area Square Meters Symbology 335n n4 n6 Gross Volume Liters 336n n4 n6 Gross Volume Cubic Meters 337n n4 n6 Kilograms per Square Meter pressure 340n n4 n6 Gross Weight Pounds 341n n4 n6 Leng...

Страница 47: ...ngle Monetary Area 393n n4 n3 n15 Amount Payable for a Variable Measure Trade Item and ISO Currency Code 400 n3 an 30 Customer s Purchase Order Number 401 n3 an 30 Consignment Number 402 n3 n17 Shipme...

Страница 48: ...ble Asset Identifier GRAI 8004 n4 an 30 EAN UCC Global Individual Asset Identifier GIAI 8005 n4 n6 Price Per Unit of Measure 8006 n4 n14 n2 n2 Identification of the Component of a Trade Item 8007 n4 a...

Страница 49: ...on a a3 a 3 Alphabetic characters 3 alphabetic characters fixed length Up to 3 alphabetic characters n n3 n 3 Numeric characters 3 numeric characters fixed length Up to 3 numeric characters an an3 an...

Страница 50: ...B CR 78 Code ID mark Disable Header STX Terminator ETX Transmission of the number of digits Disable BCC Disable Prefix Suffix None Conversion conditions Output data Code type PDF417 Data transfer rega...

Страница 51: ...effect only when the marker is permitted to light The point scan mode and the barcode reader mode see Section 8 3 cannot be enabled concurrently The one set last will be enabled 8 5 Scanning a mirror...

Страница 52: ...it QR Code symbol is read the scanner sends the data read to the host computer When scanning split QR Code symbols the scanner beeps in a different way from usual That is when the scanner reads the fi...

Страница 53: ...cifying this format allows the scanner to output multiple lines of barcode data in succession in the data transmission format selected see Section 10 3 so that the headers and terminators act as delim...

Страница 54: ...e has the wrong number of digits during registration of master data a code other than a parameter setting code is read during parameter setting by the QR coded parameter menu a transmission error or t...

Страница 55: ...receive error or command error has occurred code data read does not match the master data in the data verification mode a master code has the wrong number of digits during registration of master data...

Страница 56: ...ror has occurred during registration of a master code the verification result is a mismatch the scanner is locked or no master data has been registered in the data verification mode data transfer has...

Страница 57: ...nnerSetting_2D Scanning of a batch process QR Code symbol generated with the configuration software ScannerSetting_2D the barcode reader mode is restored after temporarily canceled The NG setting uses...

Страница 58: ...um of 30 seconds When the scanner is ready to scan that is while the trigger switch is fully held down in the momentary switching mode or when the scanner is ready to scan in the alternate switching m...

Страница 59: ...er to each of them If the host computer switches to the suspend mode when any communications software is running and recovers from that suspend mode the software may freeze in some computers Quit and...

Страница 60: ...c keypad on the connected keyboard Default Inboard numeric keys 4 Binary conversion Select the conversion type to be applied to data read from the following No conversion ASCII default Outputs 00h to...

Страница 61: ...ESC ENTER or others Terminator None TAB ESC ENTER default or others For details refer to Chapter 12 2 Prefix Suffix A prefix or suffix consists of up to eight ASCII characters 00h to FFh You can set a...

Страница 62: ...dm Without add on A X0 Linear component A X3 X0 With 2 digit add on Add on None None X1 Note 3 Linear component A X3 X0 UPC A With 5 digit add on Add on None None X2 Note 2 Without add on C X0 Linear...

Страница 63: ...th 2 digit add on Add on None None None E1 Note 3 Linear component V A E3 E0 EAN 13 With 5 digit add on Add on None None None E2 Note 3 EAN 13 CC A EAN 13 CC B CC A CC B None Y Note 3 e0 Note 3 Withou...

Страница 64: ...ssion enabled Code 39 3 Scanning enabled with a check digit Check digit transmission disabled 0 Scanning enabled without a check digit 1 Scanning enabled with a check digit Check digit transmission en...

Страница 65: ...data read The code number and the number of splits are 1 byte each and the parity 2 bytes in hexadecimal format PDF417 MicroPDF MaxiCode and Data Matrix Code data read will be transmitted as is UPC A...

Страница 66: ...X6 X7 X8 X9 X10 C D X11 X12 X13 X14 X15 Yn Flag number characters X11 15 Add on code data You can select whether or not to transmit a check digit A code ID mark precedes add on code data under the con...

Страница 67: ...acked Code data read will be transmitted as is RSS Composite symbols Code data read will be transmitted as is Under the conditions Code ID mark Type 1 and Code ID mark output mode Separating a separat...

Страница 68: ...ved as a BMP or JPEG image in 1 64 VGA or 1 4 VGA respectively You can select the output format image size output image area and whether or not to use a thumbnail by modifying the parameters of the IM...

Страница 69: ...the IMAGEOUT command should be uppercase or numerical ASCII characters Transmission condition settings such as header terminator and transmission speed for the image transmission are the same as those...

Страница 70: ...USB keyboard interface See Note 1 Chapter 10 Note 1 Selecting the USB keyboard interface disables the configuration software 2 Communications parameters for USB COM interface The following settings t...

Страница 71: ...board numeric keys Numeric data transmission format 0 to 9 Numeric keypad See Note 3 No conversion ASCII Binary conversion Binary conversion See Note 2 Kanji conversion Section 13 2 3 ms 6 ms 10 ms 16...

Страница 72: ...63 Items Parameters Defaults Refer to None STX ETX CR LF CR LF TAB ESC ENTER Right Ctrl Header User defined None STX ETX CR LF CR LF TAB ESC ENTER Right Ctrl Terminator User defined Section 10 3 1...

Страница 73: ...3 Enable Point scan mode Disable Section 8 4 5 Data transmission format Items Parameters Defaults Refer to Enable Prefix transmission Disable Enable Suffix transmission Disable Section 10 3 2 Enable C...

Страница 74: ...ata Matrix Square Disable Enable Scanning Data Matrix Rectangular Disable Section 13 2 See Note 1 QR Code min version readable 1 QR Code max version readable 1 to 40 40 MicroQR min version readable 1...

Страница 75: ...digit add on only Enable 5 digit add on only Scanning UPC EAN with add on Disable Section 13 2 Interleaved 2of5 Items Parameters Defaults Refer to Enable without a check digit Enable with a check dig...

Страница 76: ...anning Code 39 Disable Section 13 2 Min number of digits to scan for Code 39 1 digit Max number of digits to scan for Code 39 1 to 99 digits excluding start stop codes 99 digits See Note 1 Enable Tran...

Страница 77: ...mposite symbols Disable Enable Scanning RSS Composite with CC A Disable Enable Scanning RSS Composite with CC B Disable Enable Scanning UPC EAN Composite with CC A Disable Enable Scanning UPC EAN Comp...

Страница 78: ...the 1st line Max 99 digits Not specified Code type for the 2nd line Selectable from readable bar codes Not specified Heading characters for the 2nd line Up to 2 ASCII characters Not specified Min num...

Страница 79: ...ibility level in auto sensing mode Low Section 6 4 Data retransfer function Specific character transfer function Readable code switching function Marker mode switching function Ready standby switching...

Страница 80: ...e 1 Permit Data transfer regardless of error result in data editing Prohibit Data string extraction Data block extraction Data extraction mode AI prefixed string extraction Head position Tail position...

Страница 81: ...table from AI candidates Note 2 00 AI delimited mode AI 3 Selectable from AI candidates Note 2 00 Header Terminator Comma Delimiters in AI delimited mode Tab Enable Transmission of ERROR command at th...

Страница 82: ...tting QR Code symbol The beeper sounds three times Scanning the All defaults QR Code symbol in the QR coded parameter menu makes all items in the menu revert to the factory defaults TIP Beeper volume...

Страница 83: ...ll defaults End setting The beeper volume can be set by scanning the following QR Code symbol only No Start setting or End setting QR Code symbol required to be scanned Adjusting the beeper volume Sca...

Страница 84: ...rface Communications protocol USB COM interface Non acknowledge mode default ACK NAK mode Header USB COM interface None default STX Terminator USB COM interface ETX CR default LF CR LF Transmission of...

Страница 85: ...s parameters for USB keyboard interface Conversion to binary data No conversion default ASCII Binary conversion Kanji conversion Header USB keyboard interface None default STX ETX CR LF CR LF TAB ESC...

Страница 86: ...77 Header USB keyboard interface Terminator USB keyboard interface None STX ETX CR LF CR LF TAB ESC ENTER default Right Ctrl...

Страница 87: ...78 Header USB keyboard interface Data transmission format Transmission of code ID mark Disable default Enable Transmission of the number of digits Disable default Enable...

Страница 88: ...canning black and white inverted codes Black cells bars on a white background default White cells bars on a black background Automatically identify black and white inverted codes Scanning split QR Cod...

Страница 89: ...Scanning Data Matrix Disable Enable default Bar codes Scanning UPC A UPC E EAN 13 and EAN 8 Disable Enable default Scanning Interleaved 2of5 Disable Enable without a check digit default Enable with a...

Страница 90: ...nning Codabar NW 7 Disable Enable without a check digit default Enable with a check digit Check digit transmission enabled Enable with a check digit Check digit transmission disabled Transmission of s...

Страница 91: ...enabled Enable with a check digit Check digit transmission disabled Transmission of start stop codes for Code 39 Disable default Enable Other settings Trigger switch control Auto off mode default Alte...

Страница 92: ...83 Beeper control Disable Enable default Indicator LED Disable Enable default Vibrator OK vibrations default NG vibrations Disable...

Страница 93: ...scanner are different from those of the connected host Change the communications conditions of the scanner to match those of the connected host Any device driver other than our USB COM device driver...

Страница 94: ...bar codes Elevation angle skew 35 Tilt angle pitch 35 Light source LED red Scanning specifications Reading confirmation Blue LED beeper and vibrator Interface USB COM interface USB keyboard interface...

Страница 95: ...OFF or LOFF command the scanner switches to standby as long as the trigger switch control is set to continuous reading mode 1 or 2 R Note 1 READON LON Ready to scan Upon receipt of the R READON or LON...

Страница 96: ...tion match If code data scanned matches master data in data verification mode the scanner sends this command as long as the OK transmission is enabled for a match NG Verification mismatch If code data...

Страница 97: ...88 Appendix 3 Interface Specifications USB Interface Type A USB Connector Viewed from pin side Pin No Signal 1 5 VDC 2 D 3 D 4 GND 4 2 1 3...

Страница 98: ...2D Code Handy Scanner GT10Q SU GT11Q SU GT10Q HU GT11Q HU User s Manual First Edition January 2004 Fourth Edition November 2005 DENSO WAVE INCORPORATED...

Страница 99: ...DENSO WAVE INCORPORATED 4 2 12 Toranomon Minato ku Tokyo Japan 105 0001 http www denso wave com 496899 0311...

Отзывы: