547
Appendices
Appendix H
Programming Notes
■
Program file named APLINT.PD3
If a program file named APLINT.PD3 is stored in the BHT, the System Mode initiation
sequence (by pressing the PW key with the SF and 1 keys held down) will not start System
Mode but execute that user program.
Making a program file named APLINT.PD3 allows you to:
- enter an ID number at the start of System Mode and
- set the condensed System Mode which is used for maintenance of user programs.
To terminate the APLINT.PD3 file, you use the
END
or
POWER
OFF
statement. When ter-
minating the file with the
END
statement, you may start System Mode by setting the port
6000h as listed below.
Port No.
Bit assignment
Controls the following:
6000h
0
0: Not start System Mode (default)
1: Start System Mode
Содержание BHT-BASIC 100 SERIES